Indicators |
Power / TST |
This green LED is turned on when power is applied
to the media converter. Otherwise it is off. The LED will blink slowly
when in Loopback test mode. |
Fiber link 1 / Receive activity (LK1) |
This green LED is operational only when power is applied.
The LED is on when the 100Base-X link is on and flashes with a 50%
duty cycle when data is received. |
Fiber link 2 on / Receive activity (LK2) |
This green LED is operational only when power is applied.
The LED is on when the 100Base-X link is on and flashes with a 50%
duty cycle when data is received. |
Switches: On-Board (If Auto/Switch strap is set to Switch) |
Link Pass Through |
Enabled (Default) - When the state of the receiver is
changed on one of the 100Base-X interfaces it is reflected on the other
100Base-X fiber transmitter.
When a Far-End Fault Indication is received on the fiber
interface the 100Base-TX transmitter is turned off. When the Far-End
Fault Indication is cleared the transmitter is turned back on.
If disabled , the 100Base-X fiber interfaces operate
independently. Far-End Fault indication on the 100Base-FX fiber
interface has no effect on the other interface. |
Far-End Fault (FEF) |
Enabled (Default) - the media converter transmits
the Far-End Fault Indication over the fiber connection whenever a
receive failure is detected. The media converter continuously monitors
the fiber connection and clears the Far-End Fault Indication condition
when a valid signal is received.
When Disabled, Far-End Fault Indications are not
transmitted regardless of the condition of the receive signal on the
100Base-X fiber connection. |
Remote Loopback #1 |
The media converter can perform a loopback on the link #1 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. Link #2's fiber transmitter is taken off the interface. |
Remote Loopback #2 |
The media converter can perform a loopback on the link #2 fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. Link #1's fiber transmitter is taken off the interface. |
Configuration Mode (Strap) |
Auto (default) enable management module to overwrite hardware switch settings
Switch - Use onboard DIP switches |
Cables |
Fiber Optic Cable |
Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron
Single Mode: 9/125 micron (ITU-T 625) |
Packet Transmission Characteristics |
Bit Error Rate (BER) |
<10 -12 |
Environmental Specifications |
Operating Temperature |
0 C to 50 C (32 F to 122 F) |
Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Heat Output
( BTU/Hr ) |
11.9 |
Maximum Power Consumption ( Watts ) |
3.5 |
MTBF (Hours) |
484,202 |
Mechanical - Hot Swapping Card |
Edge Connecter |
32 pin DIN 41612 / IEC 60603-2 Type B/2 Male. Fist make, last break for ground and power |
Card insertion and removal |
Captive thumb screws enable fast insertion and removal. Can be further tighten with a screwdriver. |
Product Weight |
Weight |
0.15 kg, 0.33 lbs |
Packaging |
Shipping Weight |
0.33 kg, .73 lbs |
Shipping Dimensions |
203 x 38 x 152 mm, 8 x 1.5 x 6 inches |
Regulatory Approvals |
Emissions |
FCC Part 15 Class A, EN55022 Class A |
CISPR 22 Class A |
EN61000-3-2 |
Immunity |
EN55024 |
Electrical Safety |
UL 60950-1 |
EN60950 |
CE |
Laser Safety |
EN 60825-1:2007 |
Fiber optic transmitters on this device meet Class 1 Laser safety requirements
per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11. |
Environmental |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
Reach compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Lifetime warranty |