Ethernet
|
Port
|
1 port RJ45 – 10/100/1000 Base-T - Shielded
|
Auto-MDIX
|
Auto-MDIX enables proper operation with either straight-through or crossover cabling
|
Distance
|
Distance up to 100 meters ( 328 feet ) as per IEEE 802.3
|
Maximum Frame Size
|
1522 bytes
|
VDSL – Interlink
|
RJ45, BNC, Terminal Block
|
TIP and RING are polarity insensitive. Surge suppresion of 400 volts between TIP and RING
Choice of RJ45, BNC or terminal block models for VDSL link connector
- RJ45 – RING pin 4, TIP pin 5 (TIA 568 A/B)
- BNC – Coaxial 75 ohm cable with BNC connector
- Terminal Block – 2 position screw connectors for use with twisted pair telephone cabling
|
Cabling
|
Ethernet Extenders must be connected in pairs using
unconditioned wire between 19 ( 0.9 mm ) and 26 AWG ( 0.44 mm ).
Circuits that run through signal equalization equipment are not
permitted.
|
VDSL2 Line Rate/Reach
|
Actual distance and rates experienced will depend on condition
and gauge of wire used. This Rate/Reach table applies to 24 AWG ( 0.5
MM ) twisted pair wiring on RJ45 (RJ) and terminal block (TB) models.
High Speed Asymmetric
|
Reach ( Distance )
|
VDSL Rate ( Mbps )
|
feet
|
meters
|
Downstream
|
Upstream
|
250
|
76
|
195
|
105
|
500
|
152
|
182
|
98
|
1000
|
305
|
141
|
63
|
1500
|
457
|
93
|
45
|
2000
|
610
|
66
|
30
|
2500
|
762
|
53
|
12
|
3000
|
914
|
44
|
8
|
3500
|
1000
|
36
|
5
|
High Speed Symmetric
|
Reach ( Distance )
|
VDSL Rate ( Mbps )
|
feet
|
meters
|
Downstream
|
Upstream
|
250
|
76
|
190
|
110
|
500
|
152
|
180
|
105
|
1000
|
305
|
122
|
83
|
1500
|
457
|
84
|
50
|
2000
|
610
|
64
|
26
|
2500
|
762
|
53
|
10
|
3000
|
914
|
42
|
7
|
3500
|
1000
|
36
|
4
|
Long Reach Symmetric
|
Reach ( Distance )
|
VDSL Rate ( Mbps )
|
feet
|
meters
|
Downstream
|
Upstream
|
250
|
76
|
76
|
57
|
1000
|
305
|
74
|
49
|
2500
|
762
|
52
|
10
|
4000
|
1219
|
28
|
2
|
5500
|
1676
|
15
|
1.5
|
7000
|
2134
|
8
|
1.4
|
8500
|
2591
|
5
|
1.3
|
10000
|
3000
|
2
|
0.9
|
Long Reach Asymmetric
|
Reach ( Distance )
|
VDSL Rate ( Mbps )
|
feet
|
meters
|
Downstream
|
Upstream
|
250
|
76
|
78
|
16
|
1000
|
305
|
76
|
16
|
2500
|
762
|
52
|
10
|
4000
|
1219
|
28
|
2
|
5500
|
1676
|
15
|
1.5
|
7000
|
2134
|
8
|
1.4
|
8500
|
2591
|
5
|
1.3
|
10000
|
3000
|
2
|
0.9
|
|
Chassis Module
|
Compatible chassis
|
Module occupies a single slot in
Perle Converter Chassis
|
Indicators
|
Power / TST
|
This green LED is turned on when power is applied to the
Ethernet Extender. Otherwise it is off. The LED will blink when in
Loopback test mode.
|
CO - Local
|
Ethernet Extender is operating in CO VDSL mode
|
CPE - remote
|
Ethernet Extender is operating in CPE VDSL mode
|
ILNK
|
Indicates Link Status and activity on the Interlink (VDSL) port
|
ETH
|
Indicates link status and activity on Ethernet port.
|
Switches – On-board PCB
|
Rate/Reach
|
Two switches enable the user to select the right balance between speed and distance for their environment.
|
Signal to Noise Ratio
|
Selectable Signal to Noise Ratio (SNR) of 6dB or 9dB. The
higher SNR number provides better impulse noise protection but lowers
performance.
|
Auto-Negotiation (802.3u)
|
Enabled (Default) - The Ethernet Extender uses 802.3u Auto-negotiation on the 10/100/1000Base-T interface. It is set to advertise full duplex.
Disabled - The Ethernet Extender sets the port according to the position of the speed and duplex switches.
|
Link Mode
|
Standard (Default) – The 10/100/1000Base-T link remains active independent of the state of the Ethernet link on its remote peer.
Link Pass-Through- the state of the 10/100/1000Base-T
Ethernet connection is “passed through” or propagated across the VDSL
link to the 10/100/1000Base-T Ethernet link on its remote Ethernet
Extender peer. This enables a managed switch to report the state of the
remote device to its network management system.
|
Interlink Fault Feedback
|
Enabled - A loss of VDSL link will drop the 10/100/1000 Ethernet port on each end until the link recovers
Disabled ( Default ) – The state of the VDSL link is not propagated to the 10/100/1000Base-T port
|
Loopback
|
Enabled - The VDSL interlink will perform a loopback function, retransmitting all received Ethernet frames back to its peer.
Disabled (Default - Up)
|
Set Ethernet Speed
|
When Auto-Negotiation switch is disabled, fixed speed can be set
100 (Default)
10
|
Set Ethernet Duplex
|
When Auto-Negotiation switch is disabled, Duplex can be set
Full (Default)
Half
|
Environmental Specifications
|
Operating Temperature
|
0 C to 50 C (32 F to 122 F)
|
Storage Temperature
|
minimum range of -25 C to 70 C (-13 F to 158 F)
|
Operating Humidity
|
5% to 90% non-condensing
|
Storage Humidity
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Heat Output
( BTU/HR )
|
13.1
|
Power Consumption
( Watts )
|
3.8
|
MTBF (Hours)*
|
466,387
|
Packaging
|
Shipping Weight
|
0.25 kg, 0.55 lbs
|
Shipping Dimensions
|
150 x 210 x 40 mm, 5.9 x 8.3 x 1.6 inches
|
Regulatory Approvals
|
Emissions
|
FCC Part 15 Class A, EN55022 Class A
|
CISPR 22 Class A
|
EN61000-3-2
|
Immunity
|
EN55024
|
Electrical Safety
|
UL 60950-1
|
EN60950
|
CE
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A991A
|
HTSUS Number: 8517.62.0050
|
Perle Lifetime warranty
|