Power
|
Dual Power Input
|
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
12/24/48 VDC Nominal. ( 9.6 to 60 VDC)
24 VAC Nominal ( 18 to 30 VAC )
|
Power Connector
|
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
|
Maximum Current Consumption @24 vDC
|
1 SFP = 0.66 amps
2 SFP = 0.58 amps
3 SFP = 0.61 amps
5 SFP = 0.61 amps
|
Maximum Power Consumption @24 vDC
|
1 SFP = 15.8 watts
2 SFP = 14 watts
3 SFP = 14.7 watts
5 SFP = 14.7 watts
|
Overload Current Protection
|
Fused overload current protection
|
Reverse polarity protection
|
The positive and negative inputs can be reversed providing safe and simple power connectivity.
|
Access Ports
|
RJ45
|
4, 6, 7 or 8 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
Ethernet isolation 1500 V
|
RJ45 Serial Console port
|
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
|
Small Form Factor Pluggable ( SFP ) slot
|
1,2 or 3 SFP slots for SERDES 100/1000Base-X SFP modules supplied by Perle, Cisco or other manufacturers of MSA compliant SFPs
SFPs supporting the SGMII protocol are also supported ( example 1000Base-T )
|
USB Serial Console port
|
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
|
Digital Inputs
|
Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
|
Alarms
|
- NC (Normally Closed ) or NO ( Normally Open ) dry contact.
- 1A @ 24V
|
Switch Properties
|
Standards
|
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
EEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
|
Processing Type
|
Store and Forward
|
MAC Address Table Size
|
8K
|
VLAN ID range
|
1 to 4000
|
IGMP groups
|
1024
|
Packet Buffer Memory
|
1 Mbit
|
Jumbo Frame Size
|
10 KB
|
Indicators
|
Power
|
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
|
System
|
Indicates whether the switch O/S is operating normally
|
RJ45 Ethernet
|
These integrated colored LEDs indicate link, activity and speed for each port.
|
Fiber Link
|
Fiber link LED indicates Link and Data Activity
|
Alarm
|
The alarm LED ( Red ) will be turned on under alarm conditions
|
P-Ring Master LED
|
Status of the P-Ring Master
|
Backup Network Coupling
|
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
|
External Configuration DIP Switches
|
S2
|
When enabled, designates this switch as the Ring Master
|
S1
|
Activate Backup Coupling between 2 ring networks
|
Environmental Specifications
|
MTBF
|
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
|
Operating Temperature Ranges
|
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
|
Storage Temperature Range
|
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
|
Operating Humidity Range
|
5% to 90% non-condensing
|
Storage Humidity Range
|
5% to 95% non-condensing
|
Maximum Heat Output
|
1 SFP = 53.9 Btu/hr
2 SFP = 47.8 Btu/hr
3 SFP = 50.2 Btu/hr
5 SFP = 50.2 Btu/hr
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Chassis
|
Metal with an IP20 ingress protection rating
|
Din Rail Mountable
|
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
|
Product Weight and Dimensions
|
Weight
|
1.5 kg
|
Dimensions
|
75 x 130 x 121mm
|
Packaging
|
Shipping Weight
|
2.0 kg
|
Shipping Dimensions
|
170 x 260 x 70 mm
|
Standards and Certifications
|
Safety
|
UL 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
|
Emissions
|
FCC 47 Part 15 Class A
CISPR 22:2008/EN55022:2010 (Class A)
CISPR 24:2010/EN 55024:2010
|
EMC and Immunity
|
- CISPR 24:2010/EN 55024:2010
- IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 4kv, Air discharge +/- 8kv
- IEC/EN 61000-4-3 (RS) : 80mhz to 1Ghz ; 10v/m, 1.4Gkz to 2.0ghz ; 5 v/m, 2.0ghz to 2.7 ghz ; 5 v/m
- IEC/EN 61000-4-4 (EFT) : DC power line +/- 2kv, data line +/- 1kv
- IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 1kv, Line/Earth +/- 2kv, data line /earth +/- 2kv
- IEC/EN 61000-4-6 (CS) :150khz-80Mhz 10vrms
- IEC/EN 61000-4-8 (Magnetic Field) :30 A/M
- IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
|
Industrial Safety
|
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
|
Hazardous Locations ( Hazloc )
|
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 ) *
ATEX Class 1 Zone 2 *
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A991
|
HTSUS Number: 8517.62.0050
|
5 year Warranty
|
Contents Shipped
|
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
|