The IDS-509GPP is a 9 port Managed PoE+ Switch that can operate in industrial environments providing advanced performance and enabling real-time deterministic network operation. These PoE Switches are classified as Power Sourcing Equipment (PSE). While using standard UTP cables that carry Ethernet data, the IDS-509GPP has 6 ports that also provide up to 30 watts of power to Powered Devices (PDs) such as wireless access points, Voice over IP phones and IP cameras. Learn more about PoE.
Choose any combination of 10/100/1000-Base-T Ethernet copper ports and 1000Base-X fiber ports to meet the needs of your environment.
7 copper, 2 fixed SC/ST fiber ports
6 copper, 3 fixed SC/ST fiber ports
In addition to extending links over greater distances, utilizing fiber is critical in industrial plants where high levels of electromagnetic interference or EMI is a common phenomenon. This interference can cause corruption of data over copper-based Ethernet links. Data transmitted over fiber optic cable however is completely immune to this type of noise ensuring optimal data transmission across the plant floor.
With over 82 models, the Perle IDS-509GPP offers a choice of connectors, fiber types, temperature support and operating distances.
Perle Industrial-grade Ethernet Switches are designed to stand up to extreme temperatures, surges, vibrations, and shocks found in industrial automation, government, military, oil and gas, mining and outdoor applications.
Simple Plug and Play installation to get your Ethernet devices networked immediately is available with Perle’s Fast Setup feature. The familiar Command Line Interface ( CLI ), via in-band Telnet or the out-band serial console port, will be appreciated by CCNA ( Cisco Certified Network Associate ) and CCNP ( Cisco Certified Network Professional ) trained engineers.
The PRO feature set in the IDS-305 is ideal for advanced environments where additional extensive security and network integration functionality is required.
AAA ( Authentication, Authorization, Accounting )security protocols: RADIUS and TACACS+
SSH, SNMPv3, Telnet and HTTPS secure management sessions
Management Access Lists (ACL) by IP address and IP Port number
Enforce Password Strength requirements
IEEE 802.1x Authentication and Port Security for protection of user access ports
Optimize the performance and intelligence of the network with Advanced Protocols: LLDP, GVRP, Voice VLANs, MSTP, GMRP, IPv4 IGMP Snooping and IPv6 MLD Snooping
The IDS-509GPP supports a comprehensive set of management functions, such as P-Ring, management VLAN, QoS, RMON, N:1 port mirroring and local alert log. In addition, the switch can be managed with an IPv6 address.
These rugged fan-less switches are hardened to provide superior reliability in -10 to 60°C. In addition, every component on every industrial (XT) model has been designed and tested to handle operating temperatures between -40 and 75C.
All Perle Industrial Ethernet Switches have a corrosion resistance aluminum case and dual redundant power input with reverse polarity and overload protection. In addition, all units only use high-end components from the leading chip manufacturers to ensure the highest level of durability and reliability.
Power
|
Dual Power Input
|
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
- 54 VDC nominal 50-57 VDC ( PoE+ IEEE 802.3at type 2 )
- 48 VDC nominal 44 to 57 VDC ( PoE IEEE 802.3af or IEEE 802.3at type 1 )
|
Power Connector
|
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
|
Overload Current Protection
|
Fused overload current protection
|
Reverse polarity protection
|
The positive and negative inputs can be reversed providing safe and simple power connectivity.
|
Access Ports
|
RJ45 Ports
|
6 or 7 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
6 ports are 30Watt PoE+. Amount of available power to PoE ports is dependent upon sufficient voltage and power being supplied to the switch
Ethernet isolation 1500 V
|
RJ45 Serial Console port
|
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
|
USB Serial Console port
|
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
|
Digital Inputs
|
Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
|
Fast Ethernet Fiber ports
|
2 or 3 100Base-X fiber port models
Duplex SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Simplex ( BIDI, single strand ) SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
PC and UPC type patch cords supported.
|
Fiber Port Specs
Fiber Type
|
Transmit
(dBm)
|
Receive
(dBm)
|
Power
Budget
(dB)
|
Wavelength
(nm)
|
IEEE
|
Core
Size
(um)
|
Modal
Bandwidth
(MHz* Km)
|
Maximum Operating
Distance
|
Min
|
Max
|
Min
|
Max
|
MMF
( Duplex SC/ST )
|
-20.0
|
-12.0
|
-31.0
|
-14.0
|
11.0
|
1310
|
100Base-FX
|
50
|
800*
|
5 km
( 3.1 mi )
|
62.5
|
500*
|
4 km
( 2.5 mi )
|
62.5
|
200
|
2 km
( 1.2 mi )
|
MMF
( Simplex SC/ST)
|
-15.0
|
0.0
|
-28.0
|
-8.0
|
13.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
62.5
|
200
|
2 km
( 1.2 mi )
|
SMF
( Duplex SC/ST )
|
-18.0
|
-7.0
|
-32.0
|
-3.0
|
14.0
|
1310
|
100Base-LX
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Simplex SC/ST )
|
-14.0
|
-8.0
|
-32.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Duplex SC/ST)
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1310
|
100Base-EX
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Simplex SC )
|
-8.0
|
-3.00
|
-33.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Duplex SC/ST )
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1550
|
100Base-ZX
|
9
|
**
|
80 km
( 49.7 mi )
|
SMF
( Duplex SC/ST )
|
0.0
|
5.0
|
-35.0
|
-3.0
|
35.0
|
1550
|
100Base-ZX
|
9
|
**
|
120 km
( 74.6 mi )
|
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications
|
Alarms
|
Alarm Relay
|
- NC ( Normally Closed ) or NO ( Normally Open ) dry contact.
- 1A @ 24V
|
Removable Storage
|
MicroSD slot
|
A MicroSD flash card can be inserted for configuration files and firmware backup and restoration
|
Switch Properties
|
Standards
|
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow Control
IEEE 802.3at Power Over Ethernet
|
Processing Type
|
Store and Forward
|
MAC Address Table Size
|
8K
|
VLAN ID range
|
1 to 4094
|
IGMP groups
|
1024
|
Packet Buffer Memory
|
1 Mbit
|
Jumbo Frame Size
|
10 KB
|
Indicators
|
Power
|
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
|
System
|
Indicates whether the switch O/S is operating normally
|
RJ45 Ethernet
|
These integrated colored LEDs indicate link, activity and speed for each port.
|
Fiber Link
|
Fiber link LED indicates Link and Data Activity
|
Alarm
|
The alarm LED ( Red ) will be turned on under alarm conditions
|
P-Ring Master LED
|
Status of the P-Ring Master
|
Backup Network Coupling
|
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
|
External Configuration DIP Switches
|
RM
|
When enabled, designates this switch as the P-Ring Master
|
BC
|
Activate Backup Coupling between 2 ring networks
|
Environmental Specifications
|
Operating Temperature Ranges
|
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
|
Storage Temperature Range
|
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
|
Operating Humidity Range
|
5% to 90% non-condensing
|
Storage Humidity Range
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Chassis
|
Metal with an IP20 ingress protection rating
|
Din Rail Mountable
|
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
|
Product Weight and Dimensions
|
Weight
|
1.5 kg
|
Dimensions
|
75 x 130 x 121mm
|
Packaging
|
Shipping Weight
|
2.0 kg
|
Shipping Dimensions
|
170 x 260 x 70 mm
|
Standards and Certifications
|
Safety
|
UL 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
|
Emissions
|
FCC 47 Part 15 Class A
CISPR 22:2008/EN55022:2010 (Class A)
CISPR 24:2010/EN 55024:2010
|
EMC and Immunity
|
CISPR 24:2010/EN 55024:2010
IEC/EN 61000-4-2 (ESD)
IEC/EN 61000-4-3 (RS)
IEC/EN 61000-4-4 (EFT)
IEC/EN 61000-4-5 (Surge)
IEC/EN 61000-4-6 (CS)
IEC/EN 61000-4-8 (Magnetic Field)
IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
|
Industrial Safety
|
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
|
Hazardous Locations ( Hazloc )
|
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 ) *
ATEX Class 1 Zone 2 *
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A992
|
HTSUS Number: 8517.62.0050
|
5 year Warranty
|
Contents Shipped
|
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
|
Power
|
Dual Power Input
|
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
- 54 VDC nominal 50-57 VDC ( PoE+ IEEE 802.3at type 2 )
- 48 VDC nominal 44 to 57 VDC ( PoE IEEE 802.3af or IEEE 802.3at type 1 )
|
Power Connector
|
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
|
Overload Current Protection
|
Fused overload current protection
|
Reverse polarity protection
|
The positive and negative inputs can be reversed providing safe and simple power connectivity.
|
Access Ports
|
RJ45 Ports
|
6 or 7 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
6 ports are 30Watt PoE+. Amount of available power to PoE ports is dependent upon sufficient voltage and power being supplied to the switch
Ethernet isolation 1500 V
|
RJ45 Serial Console port
|
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
|
USB Serial Console port
|
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
|
Digital Inputs
|
Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
|
Fast Ethernet Fiber ports
|
2 or 3 100Base-X fiber port models
Duplex SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Simplex ( BIDI, single strand ) SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
PC and UPC type patch cords supported.
|
Fiber Port Specs
Fiber Type
|
Transmit
(dBm)
|
Receive
(dBm)
|
Power
Budget
(dB)
|
Wavelength
(nm)
|
IEEE
|
Core
Size
(um)
|
Modal
Bandwidth
(MHz* Km)
|
Maximum Operating
Distance
|
Min
|
Max
|
Min
|
Max
|
MMF
( Duplex SC/ST )
|
-20.0
|
-12.0
|
-31.0
|
-14.0
|
11.0
|
1310
|
100Base-FX
|
50
|
800*
|
5 km
( 3.1 mi )
|
62.5
|
500*
|
4 km
( 2.5 mi )
|
62.5
|
200
|
2 km
( 1.2 mi )
|
MMF
( Simplex SC/ST)
|
-15.0
|
0.0
|
-28.0
|
-8.0
|
13.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
62.5
|
200
|
2 km
( 1.2 mi )
|
SMF
( Duplex SC/ST )
|
-18.0
|
-7.0
|
-32.0
|
-3.0
|
14.0
|
1310
|
100Base-LX
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Simplex SC/ST )
|
-14.0
|
-8.0
|
-32.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Duplex SC/ST)
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1310
|
100Base-EX
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Simplex SC )
|
-8.0
|
-3.00
|
-33.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Duplex SC/ST )
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1550
|
100Base-ZX
|
9
|
**
|
80 km
( 49.7 mi )
|
SMF
( Duplex SC/ST )
|
0.0
|
5.0
|
-35.0
|
-3.0
|
35.0
|
1550
|
100Base-ZX
|
9
|
**
|
120 km
( 74.6 mi )
|
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications
|
Alarms
|
Alarm Relay
|
- NC ( Normally Closed ) or NO ( Normally Open ) dry contact.
- 1A @ 24V
|
Removable Storage
|
MicroSD slot
|
A MicroSD flash card can be inserted for configuration files and firmware backup and restoration
|
Switch Properties
|
Standards
|
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow Control
IEEE 802.3at Power Over Ethernet
|
Processing Type
|
Store and Forward
|
MAC Address Table Size
|
8K
|
VLAN ID range
|
1 to 4094
|
IGMP groups
|
1024
|
Packet Buffer Memory
|
1 Mbit
|
Jumbo Frame Size
|
10 KB
|
Indicators
|
Power
|
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
|
System
|
Indicates whether the switch O/S is operating normally
|
RJ45 Ethernet
|
These integrated colored LEDs indicate link, activity and speed for each port.
|
Fiber Link
|
Fiber link LED indicates Link and Data Activity
|
Alarm
|
The alarm LED ( Red ) will be turned on under alarm conditions
|
P-Ring Master LED
|
Status of the P-Ring Master
|
Backup Network Coupling
|
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
|
External Configuration DIP Switches
|
RM
|
When enabled, designates this switch as the P-Ring Master
|
BC
|
Activate Backup Coupling between 2 ring networks
|
Environmental Specifications
|
Operating Temperature Ranges
|
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
|
Storage Temperature Range
|
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
|
Operating Humidity Range
|
5% to 90% non-condensing
|
Storage Humidity Range
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Chassis
|
Metal with an IP20 ingress protection rating
|
Din Rail Mountable
|
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
|
Product Weight and Dimensions
|
Weight
|
1.5 kg
|
Dimensions
|
75 x 130 x 121mm
|
Packaging
|
Shipping Weight
|
2.0 kg
|
Shipping Dimensions
|
170 x 260 x 70 mm
|
Standards and Certifications
|
Safety
|
UL 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
|
Emissions
|
FCC 47 Part 15 Class A
CISPR 22:2008/EN55022:2010 (Class A)
CISPR 24:2010/EN 55024:2010
|
EMC and Immunity
|
CISPR 24:2010/EN 55024:2010
IEC/EN 61000-4-2 (ESD)
IEC/EN 61000-4-3 (RS)
IEC/EN 61000-4-4 (EFT)
IEC/EN 61000-4-5 (Surge)
IEC/EN 61000-4-6 (CS)
IEC/EN 61000-4-8 (Magnetic Field)
IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
|
Industrial Safety
|
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
|
Hazardous Locations ( Hazloc )
|
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 ) *
ATEX Class 1 Zone 2 *
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A992
|
HTSUS Number: 8517.62.0050
|
5 year Warranty
|
Contents Shipped
|
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
|
Power
|
Dual Power Input
|
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
- 54 VDC nominal 50-57 VDC ( PoE+ IEEE 802.3at type 2 )
- 48 VDC nominal 44 to 57 VDC ( PoE IEEE 802.3af or IEEE 802.3at type 1 )
|
Power Connector
|
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
|
Overload Current Protection
|
Fused overload current protection
|
Reverse polarity protection
|
The positive and negative inputs can be reversed providing safe and simple power connectivity.
|
Access Ports
|
RJ45 Ports
|
6 or 7 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
6 ports are 30Watt PoE+. Amount of available power to PoE ports is dependent upon sufficient voltage and power being supplied to the switch
Ethernet isolation 1500 V
|
RJ45 Serial Console port
|
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
|
USB Serial Console port
|
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
|
Digital Inputs
|
Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
|
Fast Ethernet Fiber ports
|
2 or 3 100Base-X fiber port models
Duplex SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Simplex ( BIDI, single strand ) SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
PC and UPC type patch cords supported.
|
Fiber Port Specs
Fiber Type
|
Transmit
(dBm)
|
Receive
(dBm)
|
Power
Budget
(dB)
|
Wavelength
(nm)
|
IEEE
|
Core
Size
(um)
|
Modal
Bandwidth
(MHz* Km)
|
Maximum Operating
Distance
|
Min
|
Max
|
Min
|
Max
|
MMF
( Duplex SC/ST )
|
-20.0
|
-12.0
|
-31.0
|
-14.0
|
11.0
|
1310
|
100Base-FX
|
50
|
800*
|
5 km
( 3.1 mi )
|
62.5
|
500*
|
4 km
( 2.5 mi )
|
62.5
|
200
|
2 km
( 1.2 mi )
|
MMF
( Simplex SC/ST)
|
-15.0
|
0.0
|
-28.0
|
-8.0
|
13.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
62.5
|
200
|
2 km
( 1.2 mi )
|
SMF
( Duplex SC/ST )
|
-18.0
|
-7.0
|
-32.0
|
-3.0
|
14.0
|
1310
|
100Base-LX
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Simplex SC/ST )
|
-14.0
|
-8.0
|
-32.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Duplex SC/ST)
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1310
|
100Base-EX
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Simplex SC )
|
-8.0
|
-3.00
|
-33.0
|
-3.0
|
18.0
|
1310 / 1550
1550 / 1310
|
100Base-BX-U
100Base-BX-D
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Duplex SC/ST )
|
-5.0
|
0.0
|
-34.0
|
-3.0
|
29.0
|
1550
|
100Base-ZX
|
9
|
**
|
80 km
( 49.7 mi )
|
SMF
( Duplex SC/ST )
|
0.0
|
5.0
|
-35.0
|
-3.0
|
35.0
|
1550
|
100Base-ZX
|
9
|
**
|
120 km
( 74.6 mi )
|
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications
|
Alarms
|
Alarm Relay
|
- NC ( Normally Closed ) or NO ( Normally Open ) dry contact.
- 1A @ 24V
|
Removable Storage
|
MicroSD slot
|
A MicroSD flash card can be inserted for configuration files and firmware backup and restoration
|
Switch Properties
|
Standards
|
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow Control
IEEE 802.3at Power Over Ethernet
|
Processing Type
|
Store and Forward
|
MAC Address Table Size
|
8K
|
VLAN ID range
|
1 to 4094
|
IGMP groups
|
1024
|
Packet Buffer Memory
|
1 Mbit
|
Jumbo Frame Size
|
10 KB
|
Indicators
|
Power
|
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
|
System
|
Indicates whether the switch O/S is operating normally
|
RJ45 Ethernet
|
These integrated colored LEDs indicate link, activity and speed for each port.
|
Fiber Link
|
Fiber link LED indicates Link and Data Activity
|
Alarm
|
The alarm LED ( Red ) will be turned on under alarm conditions
|
P-Ring Master LED
|
Status of the P-Ring Master
|
Backup Network Coupling
|
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
|
External Configuration DIP Switches
|
RM
|
When enabled, designates this switch as the P-Ring Master
|
BC
|
Activate Backup Coupling between 2 ring networks
|
Environmental Specifications
|
Operating Temperature Ranges
|
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
|
Storage Temperature Range
|
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
|
Operating Humidity Range
|
5% to 90% non-condensing
|
Storage Humidity Range
|
5% to 95% non-condensing
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Chassis
|
Metal with an IP20 ingress protection rating
|
Din Rail Mountable
|
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
|
Product Weight and Dimensions
|
Weight
|
1.5 kg
|
Dimensions
|
75 x 130 x 121mm
|
Packaging
|
Shipping Weight
|
2.0 kg
|
Shipping Dimensions
|
170 x 260 x 70 mm
|
Standards and Certifications
|
Safety
|
UL 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
|
Emissions
|
FCC 47 Part 15 Class A
CISPR 22:2008/EN55022:2010 (Class A)
CISPR 24:2010/EN 55024:2010
|
EMC and Immunity
|
CISPR 24:2010/EN 55024:2010
IEC/EN 61000-4-2 (ESD)
IEC/EN 61000-4-3 (RS)
IEC/EN 61000-4-4 (EFT)
IEC/EN 61000-4-5 (Surge)
IEC/EN 61000-4-6 (CS)
IEC/EN 61000-4-8 (Magnetic Field)
IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
|
Industrial Safety
|
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
|
Hazardous Locations ( Hazloc )
|
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 ) *
ATEX Class 1 Zone 2 *
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A992
|
HTSUS Number: 8517.62.0050
|
5 year Warranty
|
Contents Shipped
|
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100/1000Base-T ( RJ45 ) ports for Gigabit and Fast Ethernet devices
- 1000Base-X SC/ST fiber ports
-
PRO feature set including advanced switching, encryption and IEEE 1588 PTP
- PoE/PoE+ PSE capable ports, fully compliant to IEEE 802.3af/at
- IP Manageability, VLAN and resiliency management
- Digital inputs for generation of alerts
- Compact, corrosion resistant case attaches to a standard DIN Rail
- Redundant dual power input 48 VDC
- Out-of-band management via RJ45 or USB serial ports
- Programmable Controller safety and Hazardous Location Certification
- -40 to 75C industrial operating temperature ( XT Models)
|
|
|
|
|
|
|