23208278
|
28668028
|
29046218
|
29046228
|
Environmental Product Compliance
|
REACH SVHC
|
Lead 7439-92-1
|
Lead 7439-92-1
|
Lead 7439-92-1
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 25;
|
Environmentally Friendly Use Period = 25;
|
Environmentally Friendly Use Period = 25;
|
Environmentally Friendly Use Period = 25;
|
General
|
Net weight
|
2.5 kg
|
2.5 kg
|
0.9 kg
|
1.1 kg
|
Efficiency
|
> 93 % (at 400 V AC and nominal values)
|
> 94 % (at 400 V AC and nominal values)
|
typ. 93 % (400 V AC)
|
typ. 93.9 % (400 V AC)
|
Insulation voltage input/output
|
4 kV AC (type test)
|
4 kV AC (type test)
|
4 kV AC (type test)
|
4 kV AC (type test)
|
|
2 kV AC (routine test)
|
2 kV AC (routine test)
|
2.4 kV AC (routine test)
|
2.4 kV AC (routine test)
|
Insulation voltage input / PE
|
3.5 kV AC (type test)
|
3.5 kV AC (type test)
|
3.5 kV AC (type test)
|
3.5 kV AC (type test)
|
|
2 kV AC (routine test)
|
2 kV AC (routine test)
|
2.4 kV AC (routine test)
|
2.4 kV AC (routine test)
|
Insulation voltage output / PE
|
500 V DC (routine test)
|
500 V DC (routine test)
|
0.5 kV DC (type test)
|
0.5 kV DC (type test)
|
Protection class
|
I
|
I
|
I
|
I
|
Degree of protection
|
IP20
|
IP20
|
IP20
|
IP20
|
MTBF (IEC 61709, SN 29500)
|
889679,72 h (25 °C)
|
> 880000 h (25 °C)
|
> 1034000 h (25 °C)
|
> 985000 h (25 °C)
|
|
501504,51 h (40 °C)
|
> 500000 h (40 °C)
|
> 654000 h (40 °C)
|
> 638000 h (40 °C)
|
|
216825,67 h (60 °C)
|
> 216000 s (60 °C)
|
> 320000 h (60 °C)
|
> 311000 h (60 °C)
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
horizontal DIN rail NS 35, EN 60715
|
horizontal DIN rail NS 35, EN 60715
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: P
N ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: P
N <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
|
alignable: P
N ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: P
N <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
|
alignable: P
N ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: P
N <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
|
alignable: P
N ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: P
N <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
|
Operating voltage display
|
|
Green LED
|
|
|
Efficiency
|
|
|
typ. 92.6 % (480 V AC)
|
typ. 93.8 % (480 V AC)
|
Insulation voltage output / PE
|
|
|
0.5 kV DC (routine test)
|
0.5 kV DC (routine test)
|
Standards and Regulations
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Conformance with EMC Directive 2014/30/EU
|
Conformance with EMC Directive 2014/30/EU
|
Conformance with EMC Directive 2014/30/EU
|
Noise immunity
|
EN 61000-6-2:2005
|
EN 61000-6-2:2005
|
Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
|
Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
|
Connection in acc. with standard
|
CSA
|
CSA
|
|
|
Standards/regulations
|
EN 61000-4-2
|
EN 61000-4-2
|
EN 61000-4-2
|
EN 61000-4-2
|
Contact discharge
|
4 kV (Test Level 2)
|
4 kV (Test Level 2)
|
4 kV (Test Level 2)
|
4 kV (Test Level 2)
|
Standards/regulations
|
EN 61000-4-3
|
EN 61000-4-3
|
EN 61000-4-3
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
80 MHz ... 1 GHz
|
80 MHz ... 1 GHz
|
80 MHz ... 1 GHz
|
Test field strength
|
10 V/m (Test Level 3)
|
10 V/m (Test Level 3)
|
10 V/m (Test Level 3)
|
10 V/m (Test Level 3)
|
Frequency range
|
1.4 GHz ... 2 GHz
|
1.4 GHz ... 2 GHz
|
1.4 GHz ... 2 GHz
|
1.4 GHz ... 2 GHz
|
Test field strength
|
3 V/m (Test Level 2)
|
3 V/m (Test Level 2)
|
3 V/m (Test Level 2)
|
3 V/m (Test Level 2)
|
Standards/regulations
|
EN 61000-4-4
|
EN 61000-4-4
|
EN 61000-4-4
|
EN 61000-4-4
|
Comments
|
Criterion B
|
Criterion B
|
Criterion B
|
Criterion B
|
Standards/regulations
|
EN 61000-4-6
|
EN 61000-6-3
|
EN 61000-4-6
|
EN 61000-4-6
|
Frequency range
|
0.15 MHz ... 80 MHz
|
0.15 MHz ... 80 MHz
|
0.15 MHz ... 80 MHz
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
10 V (Test Level 3)
|
10 V (Test Level 3)
|
10 V (Test Level 3)
|
Low Voltage Directive
|
Conformance with LV directive 2006/95/EC
|
Conformance with LV directive 2006/95/EC
|
Conformance with Low Voltage Directive 2014/35/EC
|
Conformance with Low Voltage Directive 2014/35/EC
|
Standard - Safety of transformers
|
IEC 61558-2-17
|
|
EN 61558-2-16 (air clearances and creepage distances only)
|
EN 61558-2-16 (air clearances and creepage distances only)
|
Standard - Electrical safety
|
IEC 60950-1/VDE 0805 (SELV)
|
IEC 60950-1/VDE 0805 (SELV)
|
IEC 60950-1/VDE 0805 (SELV)
|
IEC 60950-1/VDE 0805 (SELV)
|
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
|
EN 50178/VDE 0160 (PELV)
|
EN 50178/VDE 0160 (PELV) / Overvoltage category III
|
EN 50178/VDE 0160 (PELV)
|
EN 50178/VDE 0160 (PELV)
|
Standard – Safety extra-low voltage
|
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
|
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
|
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
|
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
|
Standard - Safe isolation
|
DIN VDE 0100-410
|
DIN VDE 0100-410
|
DIN VDE 0100-410
|
DIN VDE 0100-410
|
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
|
EN 50178
|
|
|
|
Standard – Limitation of mains harmonic currents
|
EN 61000-3-2
|
EN 61000-3-2
|
EN 61000-3-2
|
EN 61000-3-2
|
Standard - Equipment safety
|
BG (design tested)
|
GS (tested safety)
|
|
|
Standard - Approval for medical use
|
IEC 60601-1, 2 x MOOP
|
|
|
|
UL approvals
|
UL Listed UL 508
|
UL Listed UL 508
|
UL Listed UL 508
|
UL Listed UL 508
|
|
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net)
|
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net)
|
UL/C-UL Recognized UL 60950-1
|
UL/C-UL Recognized UL 60950-1
|
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
Shock
|
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
|
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
|
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
|
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
|
Vibration (operation)
|
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
|
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
|
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
|
5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
|
|
15 Hz ... 150 Hz, 2.3g, 90 min.
|
|
|
|
Information technology equipment - safety (CB scheme)
|
CB Scheme
|
CB Scheme
|
|
|
Rail applications
|
EN 50121-4
|
EN 50121-4
|
EN 50121-3-2
|
EN 50121-3-2
|
Overvoltage category (EN 62477-1)
|
III
|
III
|
III (≤ 2000 m)
|
III (≤ 2000 m)
|
Standards/regulations
|
|
EN 61000-4-6
|
EN 61000-4-8
|
EN 61000-4-8
|
Standard - Safe isolation
|
|
DIN VDE 0106-101
|
|
|
Shipbuilding approval
|
|
DNV GL (EMC A), ABS, LR, RINA, NK, BV
|
DNV GL, PRS, BV, LR, ABS
|
DNV GL, PRS, BV, LR, ABS
|
Noise emission
|
|
|
Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
|
Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
|
Conducted noise emission
|
|
|
EN 55016 EN 61000-6-4 (Class A)
|
EN 55016 EN 61000-6-4 (Class A)
|
Standards/regulations
|
|
|
EN 61000-4-11
|
EN 61000-4-11
|
|
|
|
EN 61000-4-9
|
EN 61000-4-9
|
|
|
|
EN 61000-4-12
|
EN 61000-4-12
|
|
|
|
EN 61000-4-16
|
EN 61000-4-16
|
|
|
|
EN 61000-4-18
|
EN 61000-4-18
|
Standard - power supply devices for low voltage with DC output
|
|
|
EN 61204-3
|
EN 61204-3
|
EMC requirements, power plant
|
|
|
IEC 61850-3
|
|
|
|
|
EN 61000-6-5
|
|
Approval - requirement of the semiconductor industry with regard to mains voltage dips
|
|
|
SEMI F47-0706; EN 61000-4-11
|
SEMI F47-0706; EN 61000-4-11
|
Overvoltage category (EN 60950-1)
|
|
|
II (≤ 5000 m)
|
II (≤ 5000 m)
|
Overvoltage category (EN 61010-1)
|
|
|
II (≤ 5000 m)
|
II (≤ 5000 m)
|
Connection data, input
|
Connection method
|
Screw connection
|
Screw connection
|
Screw connection
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
6 mm²
|
6 mm²
|
6 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
4 mm²
|
4 mm²
|
4 mm²
|
Conductor cross section AWG min.
|
18
|
18
|
30
|
30
|
Conductor cross section AWG max.
|
10
|
10
|
10
|
10
|
Stripping length
|
7 mm
|
7 mm
|
8 mm
|
8 mm
|
Screw thread
|
M3
|
M3
|
|
|
Output data
|
Nominal output voltage
|
48 V DC ±1 %
|
24 V DC ±1 %
|
24 V DC
|
24 V DC
|
Setting range of the output voltage (U
Set)
|
30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
|
18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
|
24 V DC ... 29.5 V DC (constant capacity)
|
24 V DC ... 29.5 V DC (constant capacity)
|
Nominal output current (I
N)
|
20 A (-25 °C ... 60 °C, U
OUT = 48 V DC)
|
40 A (-25 °C ... 60 °C, U
OUT = 24 V DC)
|
10 A
|
20 A
|
POWER BOOST (I
Boost)
|
22.5 A (-25°C ... 40°C permanent, U
OUT = 48 V DC )
|
45 A (-25°C ... 40°C permanent, U
OUT = 24 V DC )
|
|
|
Selective Fuse Breaking (I
SFB)
|
100 A (12 ms)
|
215 A (12 ms)
|
60 A (15 ms)
|
120 A (15 ms)
|
Derating
|
60 °C ... 70 °C (2.5%/K)
|
60 °C ... 70 °C (2.5%/K)
|
> 60 °C (2.5%/K)
|
> 60 °C (2.5%/K)
|
Connection in parallel
|
Yes, for redundancy and increased capacity
|
Yes, for redundancy and increased capacity
|
Yes, for redundancy and increased capacity
|
Yes, for redundancy and increased capacity
|
Connection in series
|
yes
|
yes
|
yes
|
yes
|
Feedback resistance
|
max. 60 V DC
|
max. 35 V DC
|
≤ 35 V DC
|
≤ 35 V DC
|
Protection against surge voltage on the output
|
< 60 V DC
|
< 35 V DC
|
≤ 32 V DC
|
≤ 32 V DC
|
Active current limitation
|
Approx. I
BOOST = 22.5 A (for short-circuit)
|
|
|
|
Control deviation
|
< 1 % (change in load, static 10 % ... 90 %)
|
< 1 % (change in load, static 10 % ... 90 %)
|
< 0.5 % (Static load change 10 % ... 90 %)
|
< 0.5 % (Static load change 10 % ... 90 %)
|
|
< 4 % (change in load, dynamic 10 % ... 90 %)
|
< 3 % (change in load, dynamic 10 % ... 90 %)
|
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
|
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
|
|
< 0.1 % (change in input voltage ±10 %)
|
< 0.1 % (change in input voltage ±10 %)
|
< 0.25 % (change in input voltage ±10 %)
|
< 0.25 % (change in input voltage ±10 %)
|
Residual ripple
|
< 50 mV
PP (with nominal values)
|
< 40 mV
PP (with nominal values)
|
< 75 mV
PP (with nominal values)
|
< 60 mV
PP (with nominal values)
|
Output power
|
960 W
|
960 W
|
240 W
|
480 W
|
Typical response time
|
< 1 s
|
< 0.5 s
|
300 ms (from SLEEP MODE)
|
300 ms (from SLEEP MODE)
|
Maximum power dissipation in no-load condition
|
24 W
|
18 W
|
< 5 W (400 V AC)
|
< 7 W (400 V AC)
|
Power loss nominal load max.
|
70 W
|
63 W
|
< 19 W (400 V AC)
|
< 32 W (400 V AC)
|
Peak switching voltages nominal load
|
|
< 5 mV
PP (at nominal values, 20 MHz)
|
|
|
Static Boost (I
Stat.Boost)
|
|
|
12.5 A
|
25 A
|
Dynamic Boost (I
Dyn.Boost)
|
|
|
20 A (5 s)
|
30 A (5 s)
|
Maximum power dissipation in no-load condition
|
|
|
< 5 W (480 V AC)
|
< 7 W (480 V AC)
|
Power loss nominal load max.
|
|
|
< 20 W (480 V AC)
|
< 33 W (480 V AC)
|
Connection data for signaling
|
Conductor cross section solid min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
6 mm²
|
1.5 mm²
|
1.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
4 mm²
|
1.5 mm²
|
1.5 mm²
|
Conductor cross section AWG min.
|
18
|
18
|
24
|
24
|
Conductor cross section AWG max.
|
10
|
10
|
16
|
16
|
Screw thread
|
M3
|
M3
|
|
|
Connection method
|
|
|
Push-in connection
|
Push-in connection
|
Stripping length
|
|
|
8 mm
|
8 mm
|
Dimensions
|
Width
|
96 mm
|
96 mm
|
50 mm
|
70 mm
|
Height
|
130 mm
|
130 mm
|
130 mm
|
130 mm
|
Depth
|
179 mm
|
176 mm
|
125 mm
|
125 mm
|
Width with alternative assembly
|
176 mm
|
176 mm
|
122 mm
|
122 mm
|
Height with alternative assembly
|
130 mm
|
130 mm
|
130 mm
|
130 mm
|
Depth with alternative assembly
|
99 mm
|
99 mm
|
53 mm
|
73 mm
|
Weight per piece
|
2500.0 GRM
|
2954.0 GRM
|
1000.0 GRM
|
1516.8 GRM
|
Input data
|
Nominal input voltage range
|
3x 400 V AC ... 500 V AC
|
3x 400 V AC ... 500 V AC
|
3x 400 V AC ... 500 V AC
|
3x 400 V AC ... 500 V AC
|
Input voltage range
|
3x 320 V AC ... 575 V AC
|
3x 320 V AC ... 575 V AC
|
3x 400 V AC ... 500 V AC -20 % ... +10 %
|
3x 400 V AC ... 500 V AC -20 % ... +10 %
|
|
2x 360 V AC ... 575 V AC (Not approved by UL)
|
2x 360 V AC ... 575 V AC
|
2x 400 V AC ... 500 V AC -10 % ... +10 %
|
2x 400 V AC ... 500 V AC -10 % ... +10 %
|
|
450 V DC ... 800 V DC
|
450 V DC ... 800 V DC
|
± 260 V DC ... 300 V DC -13 % ... +30 %
|
± 260 V DC ... 300 V DC -13 % ... +30 %
|
AC frequency range
|
45 Hz ... 65 Hz
|
45 Hz ... 65 Hz
|
50 Hz ... 60 Hz -10 % ... +10 %
|
50 Hz ... 60 Hz -10 % ... +10 %
|
Frequency range DC
|
0 Hz
|
0 Hz
|
|
|
Discharge current to PE
|
< 3.5 mA
|
< 3.5 mA
|
< 3.5 mA
|
< 3.5 mA
|
Current consumption
|
3x 2.1 A (400 V AC)
|
3x 2.1 A (400 V AC)
|
3x 0.5 A (400 V AC)
|
3x 0.99 A (400 V AC)
|
|
3x 1.7 A (500 V AC)
|
3x 1.7 A (500 V AC)
|
3x 0.41 A (480 V AC)
|
3x 0.81 A (480 V AC)
|
|
1.7 A (600 V DC)
|
1.7 A (600 V DC)
|
2x 1.1 A (400 V AC)
|
2x 1.62 A (400 V AC)
|
Nominal power consumption
|
1386 VA
|
1342 VA
|
274 VA
|
541 VA
|
Inrush surge current
|
< 20 A (typical)
|
< 15 A
|
typ. 3 A (at 25 °C)
|
typ. 2 A (at 25 °C)
|
Mains buffering
|
typ. 25 ms (400 V AC)
|
> 25 ms (400 V AC)
|
typ. 29 ms (3x 400 V AC)
|
typ. 33 ms (3x 400 V AC)
|
|
typ. 35 ms (500 V AC)
|
> 35 ms (500 V AC)
|
typ. 26 ms (3x 480 V AC)
|
typ. 33 ms (3x 480 V AC)
|
Choice of suitable circuit breakers
|
6 A ... 16 A (AC: Characteristics B, C, D, K)
|
6 A ... 16 A (AC: Characteristics B, C, D, K)
|
3x 4 A ... 20 A (Characteristic B, C or comparable)
|
3x 4 A ... 20 A (Characteristic B, C or comparable)
|
Type of protection
|
Transient surge protection
|
Transient surge protection
|
Transient surge protection
|
Transient surge protection
|
Protective circuit/component
|
Varistor
|
Varistor, gas-filled surge arrester
|
Varistor, gas-filled surge arrester
|
Varistor, gas-filled surge arrester
|
Nominal input voltage range
|
|
|
2x 400 V AC ... 500 V AC
|
2x 400 V AC ... 500 V AC
|
|
|
|
± 260 V DC ... 300 V DC
|
± 260 V DC ... 300 V DC
|
Current consumption
|
|
|
2x 0.91 A (480 V AC)
|
2x 1.37 A (480 V AC)
|
|
|
|
3x 0.4 A (500 V AC)
|
3x 0.8 A (500 V AC)
|
|
|
|
2x 1.1 A (500 V AC)
|
2x 1.23 A (500 V AC)
|
Connection data, onput
|
Conductor cross section solid min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
6 mm²
|
1.5 mm²
|
1.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
4 mm²
|
1.5 mm²
|
1.5 mm²
|
Conductor cross section AWG min.
|
18
|
18
|
24
|
24
|
Conductor cross section AWG max.
|
10
|
10
|
16
|
16
|
Screw thread
|
M3
|
M3
|
|
|
Connection method
|
|
|
Push-in connection
|
Push-in connection
|
Stripping length
|
|
|
8 mm
|
8 mm
|
Screw thread
|
M3
|
M4
|
|
|
Ambient conditions
|
Degree of protection
|
IP20
|
IP20
|
IP20
|
IP20
|
Ambient temperature (operation)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
Ambient temperature (start-up type tested)
|
-40 °C
|
-40 °C
|
-40 °C
|
-40 °C
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
-40 °C ... 85 °C
|
-40 °C ... 85 °C
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (at 25 °C, non-condensing)
|
≤ 95 % (at 25 °C, non-condensing)
|
≤ 95 % (at 25 °C, non-condensing)
|
≤ 95 % (at 25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
3K3 (in acc. with EN 60721)
|
3K3 (in acc. with EN 60721)
|
3K3 (in acc. with EN 60721)
|
Degree of pollution
|
2
|
2
|
2
|
2
|
Installation height
|
4000 m
|
4000 m
|
≤ 5000 m (> 2000 m, observe derating)
|
≤ 5000 m (> 2000 m, observe derating)
|
Approvals
|
|
- ABS
- DNV GL
- BV
- cCSAus
- SEMI F47
- RINA
- cUL Recognized
- cUL Listed
- LR
- UL Listed
- IECEE CB Scheme
- cULus Listed
- UL Recognized
- EAC
- cULus Recognized
- NK
- CSA
- Bauartgeprüft
- CSAus
|