Serial interface
|
Interface 1
|
RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
|
Operating mode
|
Semi-duplex
|
Connection method
|
Pluggable screw connection
|
File format/coding
|
UART (11/10 bit switchable; NRZ)
|
Data direction switching
|
Automatic control, min. station response time 1 bits
|
Transmission medium
|
2-wire twisted pair, shielded
|
Transmission length
|
≤ 1200 m (depends on transmission speed, bus system and cable type)
|
Cascadability
|
9 (4,8 ... 93,75 kbps)
|
8 (115.2 kbps)
|
7 (136 kbps)
|
6 (187.5 kbps)
|
5 (375 ... 1500 kbps)
|
Termination resistor
|
390 Ω
180 Ω
390 Ω (Can be connected)
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Protocols supported
|
transparent protocol
|
Serial transmission speed
|
1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 75 / 93.75 / 115.2 / 136 / 187.5 / 375 / 500 / 1500 kbps
|
Interface 2
|
RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
|
Operating mode
|
Semi-duplex
|
File format/coding
|
UART (11/10 bit switchable; NRZ)
|
Data direction switching
|
Automatic control, min. station response time 1 bits
|
Transmission medium
|
2-wire twisted pair, shielded
|
Transmission length
|
≤ 1200 m (depends on transmission speed, bus system and cable type)
|
Cascadability
|
9 (4,8 ... 93,75 kbps)
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Protocols supported
|
transparent protocol
|
Serial transmission speed
|
1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 75 / 93.75 / 115.2 / 136 / 187.5 / 375 / 500 / 1500 kbps
|
Ambient Conditions
|
Ambient temperature (operation)
|
-40 °C ... 70 °C
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Permissible humidity (operation)
|
10 % ... 95 % (non-condensing)
|
Altitude
|
5000 m (For restrictions see manufacturer's declaration)
|
Degree of protection
|
IP20
|
Noise immunity
|
EN 50 082-2
|
General
|
Electrical isolation
|
VCC // RS-485 (A) // RS-485 (B)
|
Test voltage data interface/power supply
|
1.5 kVrms (50 Hz, 1 min.)
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Net weight
|
188.8 g
|
Housing material
|
PA 6.6-FR
|
Color
|
green
|
MTTF
|
1808 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day))
|
796 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
|
334 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day))
|
Conformance
|
CE-compliant
|
ATEX
|
II 3 G Ex nA IIC T4 Gc (Please follow the special installation instructions in the documentation!)
|
UL, USA/Canada
|
508 recognized
|
Noise emission
|
EN 50 081-1
|
Transmission channels
|
2 (1/1), TD, RD, half duplex
|
Bit delay
|
< 200 ns
|
Bit distortion
|
< 1.5 %
|
Test voltage data interfaces
|
1.5 kV AC
|
Test voltage data interface/power supply
|
1.5 kV AC
|
Degree of pollution
|
2
|
IECEx
|
Ex nA IIC T4 Gc
|
Bit distortion, input
|
max. ± 35 %
|
Bit distortion, output
|
< 3.6 %
|
Power supply
|
Nominal supply voltage
|
24 V AC/DC
|
Supply voltage range
|
18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block)
|
Typical current consumption
|
90 mA (24 V DC)
|
Max. current consumption
|
100 mA
|
Conductor cross section flexible max.
|
2.50 mm²
|
Conductor cross section flexible min.
|
0.20 mm²
|
Conductor cross section solid max.
|
2.50 mm²
|
Conductor cross section solid min.
|
0.20 mm²
|
Max. AWG conductor cross section, flexible
|
12
|
Min. AWG conductor cross section, flexible
|
24
|
Conductor cross section AWG max.
|
12
|
Conductor cross section AWG min.
|
24
|
Dimensions
|
Width
|
22.5 mm
|
Height
|
99 mm
|
Depth
|
114.5 mm
|
|
Environmental Product Compliance
|
China RoHS
|
Environmentally Friendly Use Period = 50
|
Reach and RoHS Compliant
|
Reach and RoHS Compliant
|
Standards and Regulations
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Free fall
|
In acc. with IEC 60068-2-32
Result: 1 m
|
Vibration resistance
|
In acc. with EN 60068-2-6/IEC 60068-2-6
Result: 5g, 10...150 Hz, 2.5 h, in XYZ direction
|
EMC Immunity
|
EN 61000-4-2: Contact discharge ± 6 kV (Test Level 3), Indirect discharge ± 6 kV (Test Level 3)
EN 61000-4-3: Frequency range 26 MHz ... 3 GHz (Test Level 3)
EN 61000-4-4: Criterion B
EN 61000-4-5: Signal ± 1 kV (Data line, asymmetrical)
EN 55011
EN 61000-4-6: Frequency range 0.15 MHz ... 80 MHz
|
Conformance
|
CE-compliant
|
ATEX
|
II 3 G Ex nA IIC T4 Gc
|
UL, USA/Canada
|
508 recognized
|
Noise emission
|
EN 50 081-1
|
Noise immunity
|
EN 50 082-2
|
Shock
|
In acc. with EN 60068-2-27/IEC 60068-2-27
Result: 25g, 11 ms period, half-sine shock pulse
|
Connection in acc. with standard
|
CUL
|
IECEx
|
Ex nA IIC T4 Gc
|
UL, USA/Canada
|
Class I, Div. 2, Groups A, B, C, D
|
Class I, Zone 2, AEx nA IIC T4
|
Class I, Zone 2, Ex nA IIC T4 Gc X
|
Approvals
|
|
UL Recognized
cUL Recognized
DNV
EAC
KC
cULus Recognized
UL Listed
cUL Listed
IECEx
ATEX
cULus Listed
|
Commercial data
|
Packing unit
|
1
|
Weight per piece
|
202.0 g
|
Country of origin
|
Germany
|