Technology
|
Standards
|
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LX/LHX/ZX IEEE 802.3x for Flow Control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP
|
Protocols
|
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, Syslog, DHCP Option 66/67/82, SSH, LLDP, IEEE 1588 PTP V2, EtherNet/IP, Modbus/TCP, SNMP Inform, NTP Server/Client, IPv6 (IKS-G6524A series)
|
MIB
|
MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Groups 1, 2, 3, 9
|
Flow Control
|
IEEE 802.3x flow control, back pressure flow control
|
• Switch Properties
|
Priority Queues
|
8
|
Max. Number of Available VLANs
|
256
|
VLAN ID Range
|
VID 1 to 4094
|
IGMP Groups and Multicast Route
|
1000
|
MAC Table Size
|
16 K
|
Packet Buffer Size
|
12 Mbit
|
DRAM Size
|
128 MB
|
Flash Size
|
16 MB
|
Jumbo Frame Size
|
9.6 KB
|
Switching Fabric Capacity
|
48 Gbps
|
Forwarding Rate
|
35.7 Mpps (packets per second)
|
• Interface
|
Gigabit Ethernet
|
10/100/1000BaseT(X) or 100/1000BaseSFP slot
|
Console Port
|
USB-serial console (Type B connector)
|
Storage Port
|
USB storage (Type A connector for ABC-02-USB)
|
LED Indicators
|
STATE, PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
|
Alarm Contact
|
1 relay output with current carrying capacity of 2 A @ 30 VDC
|
Digital Inputs
|
1 input with the same ground, but electrically isolated from the electronics.• +13 to +30V for state “1”
• -30 to +1V for state “0” • Max. input current: 8 mA
|
• Power Requirements
|
Input Voltage
|
110/220 VAC (85 to 264 VAC)
|
Input Current
|
Max. 0.79/0.44 A @ 110/220 VAC
|
Overload Current Protection
|
Present
|
Reverse Polarity Protection
|
Present
|
• Physical Characteristics
|
Housing
|
IP30 protection
|
Dimensions
|
440 x 44 x 386.9 mm (17.32 x 1.73 x 15.23 in)
|
Weight
|
5.1 kg
|
Installation
|
19’’ rack mounting
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Standards and Certifications
|
Safety
|
UL 60950-1, EN 60950-1
|
EMI
|
FCC Part 15 Subpart B Class A, EN 55022 Class A
|
EMS
|
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11
|
Rail Traffic
|
EN 50121-4
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
Note
|
Please check Moxa’s website for the most up-to-date certification status.
|
• MTBF (mean time between failures)
|
Time
|
IKS-G6524A: 282,390 hrs
IKS-G6824A: 280,035 hrs
|
Database
|
Telcordia (Bellcore), GB
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|