|
|
|
|
The IMC-101 industrial media converters provide industrial grade media conversion between 10/100BaseT(X) and 100BaseFX (SC/ST connectors). The IMC-101’s reliable industrial design is excellent for keeping your industrial automation applications running continuously, and each IMC-101 converter comes with a relay output warning alarm to help prevent damage and loss. The IMC-101 media converters are designed for harsh industrial environments, such as in hazardous locations (Class 1, Division 2/Zone 2, DNV, and GL Certification), and comply with FCC, TV, UL, and CE standards. The IMC-101 series is available in models that support an operating temperature of 0 to 60˚C, and an extended operating temperature of -40 to 75˚C. All IMC-101 series are subjected to a 100% burn-in test.
Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX |
• Interface |
RJ45 Ports |
10/100BaseT(X) |
Fiber Ports |
100BaseFX (SC/ST connectors) |
LED Indicators |
PWR1, PWR2, FAULT, 10/100M (TP port), 100M (Fiber port), FDX/COL (Fiber port) |
DIP Switches |
100BaseFX Full/Half duplex selection, port break alarm mask |
Alarm Contact |
One relay output with current carrying capacity of 1 A @ 24 VDC |
• Optical Fiber |
|
• Physical Characteristics |
Housing |
Metal, IP30 protection |
Dimensions |
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) |
Weight |
630 g |
Installation |
DIN-Rail mounting, wall mounting (with optional kit) |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Power Requirements |
Input Voltage |
12 to 45 VDC redundant inputs |
Input Current |
160 mA @ 24 VDC |
Connection |
Removable terminal block |
Overload Current Protection |
1.1 A |
Reverse Polarity Protection |
Present |
• Standards and Certifications |
Safety |
UL 508, UL 60950-1 |
Hazardous Location |
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC IIC |
EMC |
CE, FCC |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8,
EN 61000-4-11 |
Marine |
DNV, GL |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
Green Product |
RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) |
Time |
401,000 hrs |
Database |
MIL-HDBK-217F, GB 25°C |
• Warranty |
Warranty Period |
5 years | Dimensions (unit = mm)
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- Link Fault Pass-Through (LFP) (media converters should work as a pair)
- Power failure, port break alarm by relay output
- Redundant power inputs
- -40 to 75°C operating temperature range (T models)
- Designed for hazardous locations (Class 1 Div. 2/Zone 2)
|
|
|
|
|
|
|