Moxa is launching a new series of smart serial RS-485 remote I/O devices for industrial monitoring and control applications. The smart serial RS-485 remote I/O is the perfect choice for establishing a cost-effective, dependable, and easy-to-maintain process control remote I/O system. Serial remote I/O products offer process engineers the benefit of simple wiring, as they only use two wires to communicate with the controller or other RS-485 devices. Serial remote I/O uses the EIA RS-485 communication protocol to transmit and receive data at high speed over long distances.
In addition to communication configuration by software or USB and dual RS-485 port design, Moxa’s smart I/O devices eliminate the nightmare of extensive labor associated with the setup and maintenance of the automation system. Moxa also offers different I/O combinations, which provide greater flexibility and are compatible with every kind of application. Easy-to-use software interface for easy maintenance
Moxa’s easy-to-use ioSearch software, you can quickly access all of an ioLogik R1200 series device’s status information and settings in a user friendly graphic interface. Furthermore, ioSearch also provides an easy method for updating firmware for all ioLogik R1200 devices over an RS-485 network, so you can even update your firmware remotely. This free and easy-to-use ioSearch softwarewill reduce your maintenance time and labor effort.
Moxa’s ioLogik R1200 lets you set up your communication interface using a simple software utility. When the ioLogik R1200 is on the same RS-485 network, you no longer need to turn hundreds of dials during setup. Instead, simply configure and duplicate each ioLogik R1200’s baudrate and mode through the graphical user interface. This convenient software feature eases the effort of maintenance engineers, and greatly simplifies upgrading traditional device configuration. Innovative hardware design reduces deployment effort and enhances maintenance efficiency
With the industry’s first RS-485 serial remote I/O with USB design, Moxa provides an innovative solution for upgrading and configuring RS-485 remote I/O communication devices and firmware. All you need to do is upload the configurations to a USB drive, plug it into the field device, and all the configurations and firmware updates will upload to the field device. This innovative solution allows anyone, even someone with no technical background, to upload a device’s configurations and firmware by USB so you no longer need to bring your computer to the field site to perform routine maintenance.
Cost-saving hardware design for backup and redundancy
Moxa’s ioLogik R1200 provides dual RS-485 ports so when one of your RS-485 ports is damaged, you can quickly switch to the other RS-485 port for quick testing or repair. RS-485 remote I/O devices are already considered a low cost technology, but with dual RS-485 ports, Moxa helps you save a little bit more.
With the ioLogik R1200, you can take advantage of our dual RS-485 ports to set up wiring, provide computer redundancy, or backup your network using two computer topologies. For wiring redundancy, when your computer detects that one of the RS-485 connections is not responding, it can quickly switch over to the other RS-485 line to guarantee continuous communication between the field sensor and the central computer. Furthermore, users have the freedom to define the settings. For computer redundancy, the ioLogik R1200 provides system operators with a secure backup when one system goes down.
ioLogik R1240 Specifications
|
• Inputs and Outputs
|
Analog Inputs
|
8 channels
|
Isolation
|
3k VDC or 2k Vrms
|
• Analog Input
|
Type
|
Differential input
|
Resolution
|
16 bits
|
I/O Mode
|
Voltage / Current
|
Input Range
|
0 to 10 VDC, 0 to 20 mA, 4 to 20 mA (burn-out mode)
|
Accuracy
|
±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C ±0.5% FSR @ -40 and 75°C
|
Sampling Rate (all channels)
|
12 Hz
|
Input Impedance
|
10M ohms (min.)
|
Built-in Resistor for Current Input
|
120 ohms
|
• Power Requirements
|
Power Consumption
|
216 mA @ 24 VDC
|
Common Specifications
|
• Serial Communication
|
Interface
|
RS-485-2w: Data+, Data-, GND (5-contact terminal block for two serial port)
|
Serial Line Protection
|
ESD Protection: 15 kV Surge Protection: 1 kV
|
• Serial Communication Parameters
|
Parity
|
None, Even, Odd (default = None)
|
Data Bits
|
8
|
Stop Bits
|
1, 2 (default = 1)
|
Baudrate
|
1200 to 921.6 kbps (default = 9600)
|
High/Low Resistor for RS-485
|
1 kΩ, 150 kΩ
|
Protocols
|
Modbus RTU
|
• Physical Characteristics
|
Wiring
|
I/O cable max. 16 AWG
|
Dimensions
|
27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: -10 to 75°C (14 to 167°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Standards and Certifications
|
Safety
|
UL 508
|
EMI
|
EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class A
|
EMS
|
EN 55024, EN 61000-4-2 (ESD) Level 3, EN 61000-4-5 (Surge) Level 2, IEC 61000-4, IEC 61000-6
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
• Warranty
|
Warranty Period
|
5 years (excluding the ioLogik R1214)
|
Details
|
See www.moxa.com/warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Dual RS-485 remote I/O with built-in repeater
- Supports the installation of multi-drop communication parameters
- Install communication parameters and upgrade firmware via USB
- Upgrade firmware through an RS-485 connection
- Wide operating temperature (-40 to 85°C) models available
|
|
|
|
|
|
|