The ioPAC 8600 modular RTU controllers are 100% modular, giving users the freedom to choose CPU, power, backplane, communication, and I/O modules. In addition, the ioPAC 8600 enhances the hardware system architecture and key features of the ioPAC 8020 and ioPAC 8500 combined. It not only preserves the dual CPU architecture to support all ioPAC 8600 I/O modules, but also adds an Ethernet bus on the backplane to support Ethernet switch modules. The ioPAC 8600 supports the C/C++ and IEC 61131-3 programming languages and ready-to-run services, including Modbus, data logging, and email alarms to fulfill different customers’ requirements. With Moxa’s Active OPC Server and DA-Center data integration software, the ioPAC 8600 series provides a comprehensive solution for data acquisition and control applications in harsh environments.
Moxa’s 2-wire Ethernet technology offers system integrators an attractive option for upgrading the train’s IP network to a 10/100 Mbps* Ethernet backbone with existing 2-wire cable. This innovative 2-wire Ethernet technology supports Ethernet bypass functionality, ensuring that the Ethernet backbone will continue to operate even if one ioPAC is without power. As an added plus, with two 2-wire Ethernet modules in one ioPAC, the network can reach 200 Mbps and provide a redundant architecture.
Moxa’s ioPAC 8600 programmable controllers allow programmers to rapidly configure services (SNMP, Modbus RTU/TCP Master/Slave, E-mail/SMS alarm service, etc.) without writing any programs. The ioPAC can reduce the configuration of massively distributed deployments to a few simple mouse clicks, greatly increasing engineers’ productivity.
Moxa’s Automatic Carriage Sequencing technology quickly and automatically resets the train car sequence, without disrupting network transmissions within the train. This technology greatly reduces the operation effort required for trains that frequently rearrange consists. Onboard passenger information systems can also adjust immediately when changes are made.
The compact ioPAC 8600 is equipped with universal dual-power inputs that support all railway power voltages, and a new channel-to-channel, high voltage DI/DO module is available for use in trains that use different power systems. The ioPAC 8600 supports a variety of communication interfaces, including Ethernet, serial, CAN*, and MVB*. System integrators can control or monitor sub-systems with the ioPAC 8600, which saves space and has powerful functions to reduce both the system integrators’ budget and installation difficulties. *CAN and MVB available by project request.
• Physical Characteristics
|
Housing
|
Aluminum
|
Dimensions
|
• 5-slot version: 205.65 x 133.35 x 100 mm (8.1 x 5.25 x 3.94 in)
• 9-slot version: 324.8 x 133.35 x 100 mm (12.79 x 5.25 x 3.94 in)
|
Mounting
|
DIN-rail mounting, wall mounting (optional), and rack mounting (optional)
|
• Environmental Limits
|
Operating Temperature
|
-40 to 75°C (-40 to 176°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
Altitude
|
Up to 2000 m
|
Note
|
Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
|
• Standards and Certifications
|
Safety
|
UL 508, C1D2, ATEX Zone 2
|
EMI
|
EN 55022, EN 61000-3-2; EN 61000-3-3; FCC Part 15 Subpart B Class A
|
EMS
|
EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
|
Shock
|
IEC 60068-2-27
|
Freefall
|
IEC 60068-2-32
|
Vibration
|
IEC 60068-2-6
|
Rail Traffic
|
EN 50155*, EN 50121-3-2, EN 50121-4
|
*Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details.Note
|
Please check Moxa’s website for the most up-to-date certification status.
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Modular CPU/PWR/Backplane/IO design supporting ioPAC 8500/8600 series I/O modules
- Supports dual power module with dual power input
- Supports C/C++ and IEC 61131-3 programming languages, and ready-to-run services
- Supports 24 to 110 V power input range and DI/O modules
- Compliant with EN 50121-3-2 and EN 50121-4 specifications
|
|
|
|
|
|
|