Engineers and Project Managers that require a cost effective serial RS232-to-Ethernet solution
that is certified for the IEC 60601-1 medical safety standard must consider
the IOLAN MDC. Having the highest performance processor available along with
the Perle’s unique TrueSerial™ technology, the IOLAN MDC will provide
the most authentic serial connections across Ethernet.
Ideal for
- Hospitals that require a plug compatible Philips DevicelinkII bedside
concentrator for collecting data from bedside devices such as urimeters,
ventilators, pulse oximeters, patient monitors, infusion pumps, balloon
pumps, anesthesia machines, and cardiac output monitors
- Health care solution providers that require a terminal server certified
to IEC 60601-1 medical safety standards
- Industrial Engineers and Project Managers requiring a high performance
serial to Ethernet solution with galvanic isolation on its serial RS232
ports
Why the IOLAN MDC is the preferred choice:
- High performance 750 MIPS 32 bit processor for the best throughput
available. Ideal for time sensitive applications
- Certified for IEC 60601-1:2003 medical safety standards such as;
- Medical-grade power supply
- Standard markings and symbols used on medical equipment
- Serial ports are individually galvanic isolated for basic insulation
of 1500Vac
- Recessed serial ports comply with UL “finger test”
- Grounding stud provides a protective earth connection to the
chassis
- Capable of withstanding cleaning, sterilization or disinfection
without deterioration of safety markings
- Java-free browser access to remote serial console ports via Telnet and SSH
- FIPS 140-2 – Cryptographic modules meet US Government NIST compliancy
Hardware Specifications - IOLAN MDC - RS232 with Galvanic Isolation
|
IOLAN MDC4
|
IOLAN MDC8
|
Processor
|
MPC8349E, 400 Mhz, 750 MIPS
|
Memory
|
RAM MB
|
32
|
64
|
Flash MB
|
16
|
16
|
Interface Ports
|
Number of Serial Ports
|
4
|
8
|
Serial Port Interface
|
RS232 DTE on RJ45
|
Sun / Solaris
|
Yes
|
Serial Port Speeds *
|
50bps to 230Kbps with customizable
baud rate support
|
Data Bits *
|
5,6,7,8, 9-bit protocol support
|
Parity *
|
Odd, even, Mark, Space, None
|
Flow Control *
|
Hardware, Software, Both, None
|
Serial Port Protection
|
Galvanic Isolation - basic insulation
of 1500Vac
|
Recessed ports satisfies UL “Test
Finger”
|
15Kv Electrostatic Discharge Protection
( ESD )
|
Network
|
10/100/1000 base TX Ethernet RJ45
|
Software selectable Ethernet speed
10/100 Auto
|
Software selectable Half/Full/Auto
duplex
|
Ethernet Isolation
|
1.5Kv Magnetic Isolation
|
Power
|
Power Supply
|
USA models
|
IEC320-C13 to NEMA 5-15P line
cord
|
UK models
|
IEC320-C13 to BS1363 line cord
|
EU models
|
IEC320-C13 to CEE 7/7 Schuko
|
South Africa Models
|
IEC320-C13 to BS546 line
cord
|
Australia models
|
IEC320-C13 to AS3112 line
cord
|
|
Nominal Input Voltage:
|
110/230v AC
|
Input Voltage Range:
|
100-240v AC
|
AC Input Frequency:
|
47-63Hz
|
Current Consumption @ 100v ( Amps )
|
0.21
|
0.25
|
Current Consumption @ 240v ( Amps )
|
0.13
|
0.14
|
Typical Power Consumption ( Watts )
|
12
|
15.5
|
Power Line Protection
|
Fast transients: 1 KV ( EN61000-4-4
Criteria B )
|
Surge: 2KV ( EN61000-4-5 common mode),
1KV ( EN61000-4-5 differential and common modes
|
Indicators
|
LEDs
|
Power
|
Systems Ready
|
Network Link Activity
|
Environmental Specifications
|
Heat Output ( BTU/HR )
|
40.95
|
52.9
|
MTBF( Hours )
|
130767
|
125287
|
Operating Temperature
|
0C to 55C, 32F to 131F
|
Storage Temperature
|
-40C to 85C, -40F to 185F
|
Humidity
|
5 to 95% (non condensing) for both
storage and operation.
|
Case
|
Painted Aluminum
|
Ingress Protection Rating
|
IP40
|
Mounting
|
Universal mounting plate for
mounting on a flat wall or hospital head-wall systems
|
Product Weight and
Dimensions
|
Dimensions
|
25.9 x 27.3 x 5.0 cm
|
Weight
|
1.4 kg
|
1.4 kg
|
Packaging
|
Shippng Weight
|
34.5 x 36.5 x 9.6 cm
|
Shipping Dimensions
|
2.1 kg
|
2.1 kg
|
Regulatory Approvals
|
Emissions:
|
FCC Part 15, Subpart B, Class A
|
CFR47:2003, Chapter 1, Part 15 Subpart
B,(USA) Class A
|
ICES-003,Issue 4, February 2004 (Canada)
|
EN55022:1998 +A1:2000 + A2:2003 Class A
|
EN61000-3-2 : 1995, Limits for Harmonic
Current Emissions
|
EN61000-3-3 : 1995, Limits of Voltage
Fluctuations and Flicker
|
Immunity:
|
EN55024:1998 + A1:2001 + A2:2003
|
EN61000-4-2: Electrostatic Discharge
|
EN61000-4-3: RF Electromagnetic Field
Modulated
|
EN61000-4-4: Fast Transients
|
EN61000-4-5: Surge
|
EN61000-4-6: RF Continuous Conducted
|
EN61000-4-8: Power-Frequency Magnetic
Field
|
EN61000-4-11: Voltage Dips and Voltage
Interruptions
|
Safety:
|
IEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and
EN 60950-1 : 2006 + A11 : 2009
|
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL
60950-1,
First Edition April 1st 2003 (Recognized Component)
|
Medical Safety:
|
EN 980:2003 : Graphical symbols for
use in the labeling of medical devices
|
EN 1041:1998: Information supplied
by the manufacturer with medical devices
|
IEC 60601-1: 3rd Edition, EN60601-1:1990,
+,
A1:1993, A2:1995,
+ A11 :1994, + A12 :1994,
+ A13 :1996: Medical
electrical equipment - General requirements for safety
|
IEC 60601-1-1:2001: Medical Electrical
Equipment -
General requirements for safety - Collateral standard
|
IEC 60601-1-2:2001, EN60601-1-2:2001
Medical electrical equipment - General requirements for safety - Collateral
standard - Electromagnetic compatibility - Requirements and tests
|
UL 60601-1:2003: Medical electrical
equipment - General requirements for safety
|
CSA C22.2-601.1-M90 with S1-94 and
B-90 (R2001)
AS/NZS 3200.1.0:1998 Medical electrical equipment -
General
requirements for safety
|
Other:
|
RoHS - 2002/95/EC Directive
|
WEEE - 2002/96/EC Directive
|
CCATS - G052929
|
ECCN - 5A992A
|
HTSUS Number: 8471.80.1000
|
Warranty:
|
Perle Lifetime Warranty
|
* Features only apply when using "IOLAN" firmware
|
IOLAN MDC
|
IOLAN RJ45 Socket
|
Function
|
1
|
DTR (out)
|
2
|
TxD (out)
|
3
|
RxD (in)
|
4
|
DCD (in)
|
5
|
RTS (out)
|
6
|
CTS (in)
|
7
|
low current output (-12V)
(out) VLL *
|
8
|
low current output (+12V)
(out) VHH *
|
9
|
GND
|
10
|
Shield
|
* applicable when operating as a plug
compatible
Philips DeviceLink controller
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
Serial Port Access |
|
Connect directly using Telnet / SSH by port and IP address |
Connect with EasyPort menu by Telnet / SSH |
Use an internet browser to access with HTTP or secure HTTPS via EasyPort Web menu |
Java-free browser access to remote serial console ports via Telnet and SSH |
Ports can be assigned a specific IP address ( aliasing ) |
Multisession capability enables multiple users to access ports simultaneously |
Multihost access enables multiple hosts/servers to share serial ports |
Accessibility |
|
In-band ( Ethernet ) and out-of-band ( dial-up modem ) support |
Dynamic DNS enables users to find a console server from anywhere on the Internet |
Domain name control through DHCP option 81 |
IPV6 and IPV4 addressing support |
Availability |
|
Primary/Backup host functionality enables automatic connections to alternate host(s) |
Security |
|
SSH v1 and v2 |
SSL V3.0/TLS V1.0, SSL V2.0 |
SSL Server and SSL client mode capability |
SSL Peer authentication |
IPSec VPN : NAT Traversal, ESP authentication protocol |
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2) |
Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96 |
Key exchange: RSA, EDH-RSA, EDH-DSS, ADH |
X.509 Certificate verification: RSA, DSA |
Certificate authority (CA) list |
Local database |
RADIUS Authentication, Authorization and Accounting |
TACACS+ Authentication, Authorization and Accounting |
LDAP, NIS, Kerberos Authentication |
RSA SecureID-agent or via RADIUS Authentication |
SNMP v3 Authentication and Encryption support |
IP Address filtering |
Disable unused daemons |
Active Directory via LDAP |
Terminal Server |
|
Telnet |
SSH v1 and v2 |
Rlogin |
Auto session login |
LPD, RCP printer |
MOTD - Message of the day |
Serial machine to Ethernet |
|
Tunnel raw serial data across Ethernet - clear or encrypted |
Raw serial data over TCP/IP |
Raw serial data over UDP |
Serial data control of packetized data |
Share
serial ports with multiple hosts/servers |
Virtual modem simulates a modem connection - assign IP address by AT
phone number |
Virtual modem data can be sent over the Ethernet link with or without
SSL encryption |
TruePort com/tty redirector for serial based applications on Windows,
Vista, Linux, Solaris, SCO and HP UX. For latest drivers click here
|
"TrueSerial packet technology
provides the most authentic serial connections across Ethernet ensuring
serial protocol integrity" |
RFC 2217 standard for transport of serial data and RS232 control signals |
Customizable or fixed serial baud rates |
Plug-ins allow customer or Perle provided plug-ins for special applications |
Software Development Kit
( SDK ) available |
Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101 |
ModBus
TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus
TCP |
Data logging will store serial
data received when no active TCP session and forward to network peer
once session re-established - 32K bytes circular per port |
Console Management |
|
Sun Break Safe |
Local port buffer viewing - 256K bytes per port |
External port buffering via NFS, encrypted NFS and Syslog |
Event notification |
Manage
AC power of external equipment using Perle RPS power management products |
Clustering
- central console server enables access ports across multiple console
servers |
Windows Server 2003/2008
EMS - SAC support GUI access to text-based Special Administrative Console |
Ping watchdog probes
enable customers to power cycle equipment with attached Perle RPS power
switches in the event of an unresponsive networking gear |
Remote Access |
Dial, direct serial |
PPP, PAP/CHAP, SLIP |
|
HTTP tunneling enables firewall-safe access to remote serial devices across the internet |
Automatic DNS Update |
Utilize DHCP Opt 81 to set IOLAN domain name for easy name management
and with Dynamic DNS support , users on the Internet can access the device
server by name without having to know its IP address. See Automatic
DNS update support for details |
IPSEC VPN client/servers |
Microsoft L2TP/IPSEC VPN client ( native to Windows XP) |
Microsoft IPSEC VPN Client ( native to Windows Vista ) |
Cisco routers with IPSEC VPN feature set |
Perle IOLAN SDS/STS and SCS models |
OA&M ( Operations, Administration and Management ) |
|
SNMP V3 - read and write, Perle MIB |
Syslog |
Perle Device Manager - Windows based utility for large scale deployments |
Configurable default configuration |
Installation Wizard |
Set a Personalized Factory Default for your IOLANs |
Protocols |
|
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4,
IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast,
ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD,
RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP,
SLIP, CSLIP, RFC2217, MSCHAP |
|
|
|
|
|
|
|