Introduction
The MGate 5217I Series comprise 2-port BACnet gateways that can convert Modbus RTU/ACSII/TCP to BACnet/IP protocol. Depending on the size and the scale of the network, the gateways provide 600-point and 1200-point models. All models are rugged, DIN-rail mountable, operate in wide temperatures, and offer built-in 2kV isolation for serial signals.
Easy Configuration Via Web Console and Excel Spreadsheet
The MGate 5217I Series comes with an intuitive UI design to make configuration easy. With that, you can easily access protocol conversion modes and finish the configuration in a few steps instead of installing an additional engineering utility in your computer. Besides, the MGate can generate Modbus commands by importing an Excel spreadsheet, which makes it easy to edit Modbus commands.
Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics
The MGate 5217I gateways support Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as the wrong slave ID and register address, or an incorrect command configuration. With Diagnostics, you can check the communication status and view values at a glance. With Modbus/BACnet Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.
Security Features Based on IEC 62443
Using network devices that are IEC 62443-4-2 compliant and equipped with basic security capabilities is an effective precautionary measure to ward off cyberattacks. The MGate 5217I Series is capable of several basic security capabilities, including password cracking defense, sniffer and data breach prevention, whitelisting, and the account management.
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection
Magnetic Isolation Protection
Ethernet Software Features
Industrial Protocols
Modbus TCP Client (Master), BACnet/IP Server (Slave)
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client
MIB
Time Management
Serial Interface
No. of Ports
Connector
Serial Standards
Baudrate
Data Bits
Parity
None, Even, Odd, Space, Mark
Stop Bits
Flow Control
RTS Toggle (RS-232 only), RTS/CTS, DTR/DSR
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485
Isolation
Serial Signals
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
RS-485-2w
RS-485-4w
Modbus RTU/ASCII
Mode
Functions Supported
Max. No. of Commands
MGate 5217I-600-T: 600 (up to 300 commands/per serial port)
MGate 5217I-1200-T: 1200 (up to 600 commands/per serial port)
Modbus TCP
Mode
Functions Supported
Max. No. of Server Connections
Max. No. of Commands
MGate 5217I-600-T: 600
MGate 5217I-1200-T: 1200
BACnet/IP
Mode
Memory Size
MGate 5217I-600-T: 600 points
MGate 5217I-1200-T: 1200 points
Supported BACnet Object
Binary Input
Binary Output
Binary Value
Analog Input
Analog Output
Analog Value
Multi-state Input
Multi-state Output
Multi-state Value
Integer Value
Positive Integer Value
Power Parameters
Input Voltage
Input Current
300 mA @ 24 VAC
510 mA @ 12 VDC
Power Connector
Screw-fastened Euroblock terminal
Relays
Contact Current Rating
Resistive load: 1 A @ 30 VDC
Physical Characteristics
Housing
IP Rating
Dimensions (without ears)
29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
Dimensions (with ears)
29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
Weight
Environmental Limits
Operating Temperature
-40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
EMC
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Safety
Freefall
Shock
Vibration
IEC 60068-2-6, IEC 60068-2-64
Features
Supports Modbus RTU/ASCII/TCP master/client
Supports BACnet/IP slave/server
Supports 600 points and 1200 points models
Supports COV for fast data communication
Supports virtual nodes designed to make each Modbus device as a separate BACnet/IP device
Configures Modbus commands quickly by editing an Excel spreadsheet
Embedded traffic and diagnostic information for easy troubleshooting
Built-in Ethernet cascading for easy wiring
Industrial design with -40 to 75°C operating temperature range
Serial port with 2 kV isolation protection
Dual AC/DC power supply
5-year warranty
Security features based on IEC 62443