With the NPort® 5600 rackmount series, you not only protect your current
hardware investment, but also allow for future network expansion by centralizing
the management of your serial devices and distributing management hosts over the
network.
Network Readiness for up to 16 Serial Devices
Only basic configuration is needed with the NPort® 5600 to connect up to 16
serial devices to an Ethernet network.
19-inch Rackmount Device Server
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports on the
front panel, and 8 or 16 RJ45 serial port connectors on the rear panel. This
makes the NPort® 5600 device servers suitable for standard 19-inch rack
mounting, allowing you to simplify operational, maintenance, and administrative
tasks.
Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the NPort® 5600
recognizable as Real COM ports by Windows, or Real TTY ports by Linux. In
addition to supporting basic data transmission and reception, the NPort® drivers
also support the RTS, CTS, DTR, DSR, and DCD control signals.
LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45
connector) provide a great tool for basic maintenance tasks, and help engineers
analyze problems in the field. The LEDs not only indicate current system and
network status, but also help field engineers monitor the status of attached
serial devices.
Adjustable Termination and Pull High/Low Resistors
When using termination resistors to prevent serial signal reflection, it is
important to set the pull high/low resistors correctly so that the electrical
signal is not corrupted. Since no set of resistor values is universally
compatible for all environments, the NPort® 5600 has DIP switches on the bottom
panel for setting the termination and pull high/low resistor values.
• Ethernet Interface
|
Number of Ports
|
1
|
Speed
|
10/100 Mbps, auto MDI/MDIX
|
Connector
|
8-pin RJ45
|
Magnetic Isolation Protection
|
1.5 kV built-in
|
• Optical Fiber Interface (for -M-SC and -S-SC)
|
|
• Serial Interface
|
Number of Ports
|
8 or 16
|
Serial Standards
|
RS-232/422/485
|
Connector
|
RJ45 (8 pins)
|
RS-485 Data Direction Control
|
ADDC® (Automatic Data Direction Control)
|
Pull High/Low Resistor for RS-485
|
1 kΩ, 150 kΩ (NPort 5650-8/16)
|
• Serial Communication Parameters
|
Data Bits
|
5, 6, 7, 8
|
Stop Bits
|
1, 1.5, 2
|
Parity
|
None, Even, Odd, Space, Mark
|
Flow Control
|
DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
|
Baudrate
|
50 bps to 921.6 kbps
|
• Serial Signals
|
RS-232
|
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
|
RS-422
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-4w
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-2w
|
Data+, Data-, GND
|
• Software
|
Network Protocols
|
ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
|
Configuration Options
|
Web Console, Telnet Console, Windows Utility
|
Windows Real COM Drivers
|
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
|
Fixed TTY Drivers
|
SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
|
Linux Real TTY Drivers
|
Linux 2.4.x, 2.6.x, 3.x
|
• Mini Screen with Push Buttons (for standard temp. models)
|
LCD Panel
|
Liquid Crystal Display on the case
|
Push Buttons
|
Four push buttons for convenient on-site configuration
|
• Physical Characteristics
|
Housing
|
Metal
|
Weight
|
NPort 5650-8-S-SC, 5650-8-M-SC: 3,380 g (7.45 lb)
NPort 5650-8: 3,360 g (7.41 lb) NPort 5650-16: 3,460 g (7.63 lb) NPort 5650-16-S-SC, 5650-16-M-SC: 3,440 g (7.58 lb) NPort 5650-8-HV-T: 3,720 g (8.20 lb) NPort 5650-16-HV-T: 3,820 g (8.42 lb)
|
Dimensions
|
Without ears: 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
With ears: 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
|
Storage Temperature
|
Standard Models: -20 to 70°C (-4 to 158°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Input Voltage
|
NPort 5650: 100 to 240 VAC, 47 to 63 Hz
NPort 5650-HV: 110 VDC (88 to 300 VDC)
|
Input Current
|
NPort 5650-8/16: 158 mA @ 100 VAC, 47 to 63 Hz
NPort 5650-8/16-S-SC: 164 mA @ 100 VAC, 47 to 63 Hz NPort 5650-8/16-M-SC: 174 mA @ 100 VAC, 47 to 63 Hz NPort 5650-8/16-HV: 152 mA @ 88 VDC
|
• Standards and Certifications
|
Safety
|
UL 60950-1
|
EMC
|
EN 55022/24
|
EMI
|
CISPR 22, FCC Part 15B Class A
|
EMS
|
NPort 5650-8/16 Series:
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2.5 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs NPort 5650-8/16-HV Series: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
|
Medical
|
EN 60601-1-2 Class B, EN 55011
|
• Reliability
|
Automatic Reboot Trigger
|
Built-in WDT (watchdog timer)
|
• MTBF (mean time between failures)
|
Time
|
NPort 5650-8: 117,584 hrs
NPort 5650-16: 104,767 hrs NPort 5650-8-S-SC: 116,914 hrs NPort 5650-8-M-SC: 116,914 hrs NPort 5650-16-S-SC: 87,528 hrs NPort 5650-16-M-SC: 87,528 hrs NPort 5650-8-HV: 725,390 hrs NPort 5650-16-HV: 531,264 hrs
|
Standard
|
NPort 5650-8/5650-16/5650-8-S-SC/5650-8-M-SC/5650-16-S-SC/5650-16-M-SC: MIL-HDBK-217F
NPort 5650-8-HV/5650-16-HV: Telcordia (Bellcore) Standard TR/SR
|
• Warranty
|
Warranty Period
|
5 years
|
Details
|
See www.moxa.com/warranty
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 8 or 16 serial ports supporting RS-232/422/485
- Standard 19-inch rackmount size
- 10/100M auto-sensing Ethernet
- Built-in 15 KV ESD protection for all serial signals
- Easy IP address configuration with LCD panel
- Choice of configuration methods: Web console, Telnet console, and Windows utility
- Versatile socket operation modes, including TCP Server, TCP Client, UDP, and Real COM
- SNMP MIB-II for network management
|
|
|
|
|
|
|