Power
|
Dual Power Input
|
Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
12/24/48 VDC Nominal. ( 9.6 to 60 VDC)
24 VAC Nominal ( 18 to 30 VAC )
|
Power Connector
|
4-Pin Removable Terminal Block.
Grounding screw on metal chassis
|
Maximum Current Consumption @24 vDC
|
1 Fiber port = 0.73 amps
2 Fiber ports = 0.69 amps
3 Fiber ports = 0.66 amps
|
Maximum Power Consumption @24 vDC
|
1 Fiber port = 17.5 watts
2 Fiber ports = 16.6 watts
3 Fiber ports = 15.7 watts
|
Overload Current Protection
|
Fused overload current protection
|
Reverse polarity protection
|
The positive and negative inputs can be reversed providing safe and simple power connectivity.
|
Access Ports
|
RJ45
|
6,7 or 8 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft )
Auto-negotiation
Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
Ethernet isolation 1500 V
|
RJ45 Serial Console port
|
RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available
|
USB Serial Console port
|
MicroUSB Type B female port for serial console management. Used as an alternative port for out of band management connections
|
Digital Inputs
|
Two Digital Inputs are provided that can be used for generation of alarms ( SNMP trap, energizing of on-board Alarm Relay,etc )
|
Gigabit Fiber port
|
1, 2 or 3 1000Base-x fiber port models
Duplex SC or ST connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
Simplex ( BIDI, single strand ) SC connector
- Multimode 50/125 or 62.5/125 micron fiber cable
- Single mode 9/125 micron fiber cable
PC and UPC type patch cords supported.
|
Fiber Port Specs
Fiber Type
|
Transmit
(dBm)
|
Receive
(dBm)
|
Power
Budget
(dB)
|
Wavelength
(nm)
|
IEEE
|
Core
Size
(um)
|
Modal
Bandwidth
(MHz* Km)
|
Maximum Operating
Distance
|
Min
|
Max
|
Min
|
Max
|
MMF
( Duplex SC/ST )
|
-9.5
|
-4.0
|
-17.0
|
-3.0
|
7.5
|
850
|
1000Base-SX
|
62.5
|
160
|
220 m
(722 ft)
|
62.5
|
200
|
275 m
(902 ft)
|
50
|
400
|
500 m
(1,640 ft)
|
50
|
500
|
550 m
(1,804 ft)
|
50
|
2000
|
1000 m
(3281 ft)
|
MMF
( Duplex SC/ST )
|
-6.0
|
0.0
|
-17.0
|
0.0
|
11.0
|
1310
|
1000Base-LX
|
62.5
|
160
|
2 km
( 1.2 mi )
|
50
|
500
|
1 km
(3280ft)
|
MMF
( simplex SC )
|
-10.0
|
-4.0
|
-17.0
|
-3.0
|
7.0
|
1310 / 1550
1550 / 1310
|
1000Base-BX-U
1000Base-BX-D
|
62.5
50
|
500
|
500 m
(1,640 ft)
|
SMF
( Duplex SC/ST )
|
-9.5
|
-3.0
|
-20.0
|
-3.0
|
10.5
|
1310
|
1000Base-LX/LH
|
9
|
**
|
10 km
(6.2 mi)
|
SMF
( Simplex SC )
|
-9.0
|
-3.0
|
-20.0
|
-3.0
|
11.0
|
1310 / 1490
1490 / 1310
|
1000Base-BX-U
1000Base-BX-D
|
9
|
**
|
10 km
(6.2 mi)
|
SMF
( Simplex SC )
|
-8.0
|
-3.0
|
-22.0
|
-3.0
|
14.0
|
1310 / 1490
1490 / 1310
|
1000Base-BX-U
1000Base-BX-D
|
9
|
**
|
20 km
( 12.4 mi )
|
SMF
( Duplex SC/ST )
|
-2.0
|
2.0
|
-23.0
|
-3.0
|
21.0
|
1310
|
1000Base-EX
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Simplex SC )
|
-3.0
|
2.0
|
-23.0
|
-3.0
|
20.0
|
1310 / 1490
1490 / 1310
|
1000Base-BX-U
1000Base-BX-D
|
9
|
**
|
40 km
( 24.9 mi )
|
SMF
( Duplex SC/ST )
|
-2.0
|
5.0
|
-23.0
|
-3.0
|
21.0
|
1550
|
1000Base-ZX
|
9
|
**
|
70 km
( 43 mi )
|
SMF
( Simplex SC )
|
-2.0
|
3.0
|
-26.0
|
-3.0
|
24.0
|
1510 / 1590
1590 / 1510
|
1000Base-BX-U
1000Base-BX-D
|
9
|
**
|
80 km
( 50 mi )
|
SMF
( Duplex SC/ST )
|
0.0
|
5.0
|
-32.0
|
-9.0
|
32.0
|
1550
|
1000Base-ZX
|
9
|
**
|
120 km
( 74.6 mi )
|
SMF
( Simplex SC )
|
-3.0
|
2.0
|
-34.0
|
-9.0
|
31.0
|
1510 / 1590
1590 / 1510
|
1000Base-BX-U
1000Base-BX-D
|
9
|
**
|
120 km
( 74.6 mi )
|
SMF
( Duplex SC/ST )
|
2.0
|
5.0
|
-34.0
|
-9.0
|
36.0
|
1550
|
1000Base-ZX
|
9
|
**
|
160 km
( 100 mi )
|
* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications
|
Alarms
|
Alarm Relay
|
- NC ( Normally Closed ) or NO ( Normally Open ) dry contact.
- 1A @ 24V
|
Switch Properties
|
Standards
|
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.3z 1000BASE-X
IEEE 802.3x for Flow Control
|
Processing Type
|
Store and Forward
|
MAC Address Table Size
|
8K
|
VLAN ID range
|
1 to 4000
|
IGMP groups
|
1024
|
Packet Buffer Memory
|
1 Mbit
|
Indicators
|
Power
|
This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs
|
System
|
Indicates whether the switch O/S is operating normally
|
RJ45 Ethernet
|
These integrated colored LEDs indicate link, activity and speed for each port.
|
Fiber Link
|
Fiber link LED indicates Link and Data Activity
|
Alarm
|
The alarm LED ( Red ) will be turned on under alarm conditions
|
P-Ring Master LED
|
Status of the P-Ring Master
|
Backup Network Coupling
|
Indicates whether or not the “Backup Network Coupling” feature is enabled ( Redundant links connecting two P-Ring networks )
|
External Configuration DIP Switches
|
S2
|
When enabled, designates this switch as the Ring Master
|
S1
|
Activate Backup Coupling between 2 ring networks
|
Environmental Specifications
|
MTBF
|
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
|
Operating Temperature Ranges
|
Standard temperature models ( Std ): -10° C to 60° C (14° F to 140° F).
XT Industrial extended temperature models ( Ind ) : -40° C to 75° C ( -40 F to 167° F )
|
Storage Temperature Range
|
Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models
|
Operating Humidity Range
|
5% to 90% non-condensing
|
Storage Humidity Range
|
5% to 95% non-condensing
|
Maximum Heat Output
|
1 Fiber port = 59.7 Btu/hr
2 Fiber ports = 56.7 Btu/hr
3 Fiber ports = 53.7 Btu/hr
|
Operating Altitude
|
Up to 3,048 meters (10,000 feet)
|
Chassis
|
Metal with an IP20 ingress protection rating
|
Din Rail Mountable
|
DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
Removable to accommodate optional Panel/Wall mount kit
|
Product Weight and Dimensions
|
Weight
|
1.5 kg
|
Dimensions
|
75 x 130 x 121mm
|
Packaging
|
Shipping Weight
|
2.0 kg
|
Shipping Dimensions
|
170 x 260 x 70 mm
|
Standards and Certifications
|
Safety
|
UL 60950-1
IEC 60950-1:2005+A1:2009 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
CE Mark
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers )
|
Emissions
|
FCC 47 Part 15 Class A
CISPR 22:2008/EN55022:2010 (Class A)
CISPR 24:2010/EN 55024:2010
|
EMC and Immunity
|
- CISPR 24:2010/EN 55024:2010
- IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 4kv, Air discharge +/- 8kv
- IEC/EN 61000-4-3 (RS) : 80mhz to 1Ghz ; 10v/m, 1.4Gkz to 2.0ghz ; 5 v/m, 2.0ghz to 2.7 ghz ; 5 v/m
- IEC/EN 61000-4-4 (EFT) : DC power line +/- 2kv, data line +/- 1kv
- IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 1kv, Line/Earth +/- 2kv, data line /earth +/- 2kv
- IEC/EN 61000-4-6 (CS) :150khz-80Mhz 10vrms
- IEC/EN 61000-4-8 (Magnetic Field) :30 A/M
- IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )
|
Industrial Safety
|
UL 61010-1 and UL 61010-2-201 ( Standard for Safety for Programmable Controllers ). Formerly known as UL508 (Safety standard for Industrial Control Equipment )
|
Hazardous Locations ( Hazloc )
|
ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D ( formerly known as UL 1604 ) *
ATEX Class 1 Zone 2 *
|
Environmental
|
Reach, RoHS and WEEE Compliant
|
Other
|
ECCN: 5A991
|
HTSUS Number: 8517.62.0050
|
5 year Warranty
|
Contents Shipped
|
- Industrial Ethernet Switch with DIN Rail attachment
- Terminal block
- Installation guide
|