Features |
MCR1900-AC |
MCR1900-DAC |
MCR1900-DC |
MCR1900-DDC |
Slots |
19 slots for insertion of Perle Unmanaged Media Converter Modules or Managed Media Converter Modules with Chassis Management Module |
Intelligent Alarm Relay |
Dry Contact Relay engaged upon monitored chassis
error conditions: power failure, high temperature, backplane voltage
error, fan speed failure
3 amps @24 vDC, Normally open / normally closed contacts on removable terminal blocks |
Hot-swappable Modules |
All Media Converter modules, management module and power supplies are hot-swappable |
Power |
Nominal input voltage |
115/230 VAC |
24/48v DC |
Input Voltage Range |
90 - 264 VAC |
18 - 72v DC |
Capacity |
120 watts max.
The single power supply can provide sufficient power for a
chassis that is completely filled with media converter modules |
240 watts max.
The dual supply provides redundancy for instant fail-over. Power supplies load share |
120 watts max.
The single power supply can provide sufficient power for a
chassis that is completely filled with media converter modules |
240 watts max.
The dual supply provides redundancy for instant fail-over. Power supplies load share |
AC input frequency |
47 - 63 Hz |
N/A |
International Power Line Cords by Model |
USA: IEC320-C13 to NEMA5-15P |
Pluggable Terminal block +, - , Gnd with Reverse polarity protection |
UK: IEC320-C13 to BS1363 |
EU: IEC320-C13 to CEE717 Schuko |
South Africa / India: IEC320-C13 to BS546 |
Australia: IEC320-C13 to AS3112 |
LEDs |
Power Supply A Status |
Power Supply A and B status |
Power Supply A Status |
Power Supply A and B status |
Grounding |
Dual ground screws for #10 ring terminals or grounding lug connectors provide a reliable chassis ground connection. |
Environmental Specifications |
Heat Output ( BTU/HR ) |
17 |
29 |
19 at 24vdc, 25 at 48vdc |
34 at 24vdc, 49 at 48vdc |
MTBF (Hours) |
31,716 |
255,530 |
32,051 |
255,531 |
Operating Temperature |
0C to 50C, 32F to 122F |
Storage Temperature |
-25C to 70C, -13F to 150F |
Humidity |
5 to 95% (non-condensing) for both storage and operation. |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection Rating |
IP30 with all slots occupied |
Altitude |
up to 3,038 meters ( 10,000 ft) |
Mounting |
2U - 19" rack mounting hardware is included
2U - 23" Telcom / ETSI rack mounting hardware is optional |
Product Weight and Dimensions |
Weight |
6.32 kg, 14 lbs |
7.0 kg, 15.4 lbs |
6.39 Kg, 14.1 lbs |
7.14 kg, 15.74 lbs |
Dimensions |
356 x 435 x 89 mm, 14 x 17.2 x 3.5 in |
Packaging |
Shipping Weight |
7.76 kg, 17 lbs |
9.0 kg, 19.8 lbs |
7.76 kg, 17.11 lbs |
9.0 kg, 19.8 lbs |
Shipping Dimensions |
559 x 482 x 178 mm, 22 x 19 x 7 in |
Regulatory Approvals |
Emissions |
FCC Part 15 Class A, EN55022 Class A |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A |
ICES-003, Issue 4, February 2004 (Canada) |
EN55022:1998 + A1:2000 + A2:2003 Class A |
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions |
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker |
Immunity |
EN55024:1998 + A1:2001 + A2:2003 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic Field |
EN61000-4-11: Voltage Dips and Voltage Interruptions |
Safety |
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme. |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component) |
Environmental |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
Reach compliant |
Other |
ECCN: 5A991A |
HTSUS Number: 8517.62.0050 |
Perle Lifetime Warranty |