The CP-134U and CP-134U-I 4-port universal PCI boards are designed for industrial automation applications that require a long distance,multi-point, PC-based data acquisition solution. On-chip Automatic Data Direction Control for precision RS-485 communication
RS-485 communication requires precise timing control to enable and disable the line driver. The Moxa Turbo Serial Engine™ chip that powers the CP-134U board comes with on-chip ADDC®, which makes RS-485 as easy to use as RS-232. RS-485 multidrop for up to 31 devices within 1.2 km
The CP-134U universal PCI board has 4 RS-422/485 serial ports, each of which can achieve data rates up to 921.6 Kbps. In RS-485 mode,the board can connect up to 31 daisy-chained RS-485 devices within a range of 1.2 km. For long distance RS-485 communication, choose the CP-134U-I, which comes with 2 KV optical isolation protection to prevent equipment damage.
Drivers Provided for Windows, Linux, and Unix
Moxa continues to support a wide variety of operating systems, and the CP-134U and CP-134U-I boards are no exception. Reliable Windows COM and Linux/Unix TTY drivers are provided for all Moxa boards, and other operating systems, such as WEPOS, are also supported for embedded integration.
Hardware |
Comm.
Controller |
MU860 (16C550C
compatible) |
Bus |
32-bit Universal
PCI |
Connector |
DB44 female |
• Serial Interface |
Number
of Ports |
4 |
Serial
Standards |
2 x RS-232/422/485, 2
x RS-422/485 |
Max.
No. of Boards per PC |
4 |
• Serial Line
Protection |
ESD
Protection |
15 KV on the
board |
Optical
Isolation |
2 KV (CP-134U-I
configured for RS-422/485 only) |
• Performance |
Baudrate |
50 bps to 921.6
Kbps |
• Serial Communication
Parameters |
Data
Bits |
5, 6, 7, 8 |
Stop
Bits |
1, 1.5, 2 |
Parity |
None, Even, Odd,
Space, Mark |
Flow
Control |
RTS/CTS,
XON/XOFF |
I/O
Address |
Assigned by
BIOS |
IRQ |
Assigned by
BIOS |
• Serial Signals |
RS-232 |
TxD, RxD, RTS, CTS,
DTR, DSR, DCD, GND |
RS-422 |
TxD+(B), TxD-(A),
RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND |
RS-485-4w |
TxD+(B), TxD-(A),
RxD+(B), RxD-(A), GND |
RS-485-2w |
Data+(B), Data-(A),
GND |
• Driver Support |
Operating
Systems |
Windows 9X/ME/NT/2000,
Windows XP/2003/Vista/2008/7 x86/x64, Windows CE 5.0/6.0, Windows XP Embedded,
DOS, Linux 2.4, Linux 2.6 x86/x64, FreeBSD 4/5, QNX 6, SCO OpenServer 5/6,
UnixWare 7, Solaris 10 x86/x64 |
Note |
Please refer to Moxa's
website for the latest driver support information. |
• Physical
Characteristics |
Dimensions |
CP-134U: 82.5 x 120 mm
(3.24 x 4.72 in) CP-134U-I: 115 x 120 mm (4.52 x 4.72 in) |
• Environmental
Limits |
Operating
Temperature |
Standard Models: 0 to
55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage
Temperature |
-40 to 85°C (-40 to
185°F) |
Ambient
Relative Humidity |
5 to 95%
(non-condensing) |
• Standards and
Certifications |
EMC |
CE, FCC |
EMI |
EN 55022, EN
61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
EMS |
EN 55024, IEC
61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC
61000-4-8, IEC 61000-4-11 (DIPS) |
Green
Product |
RoHS, CRoHS,
WEEE |
• MTBF (mean time between
failures) |
Time |
480,209 hrs |
Database |
Telcordia (Bellcore),
GB |
• Power Requirements |
Power
Consumption |
CP-134U: 180 mA @ +5
V CP-134U-I: 850 mA @ +5 V |
• Warranty |
Warranty
Period |
5 years | Dimensions
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Over 700 Kbps data throughput for top performance
- 921.6 Kbps maximum baudrate for super fast data transmission
- ADDC® provides automatic data direction control for RS-485 signals
- 128-byte FIFO and on-chip H/W, S/W flow control
- Compatible with 3.3/5V PCI and PCI-X
- Drivers provided for a broad selection of operating systems, including the latest Windows and Linux
- 15 KV ESD protection on the board
- Added bonus! Ports 1 and 2 support RS-232 and RS-422/485
- Wide temperature model available for -40 to 85°C environments
|
|
|
|
|
|
|