The TCC-100 and TCC-100I are RS-232 to RS-422/485 converters that increase networking capability by extending the RS-232 transmission distance. Both converters have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, external terminal block for power, and optical isolation (TCC-100I only). The TCC-100/100I are ideal solutions for converting RS-232 signals to RS-422/485 in critical industrial environments.
RS-232 Side
|
Connector
|
DB9 female
|
Signals
|
TxD, RxD, RTS, CTS, GND
|
• RS-422/485 Side
|
Connector
|
Terminal Block
|
Signals
|
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w: Data+, Data-, GND
|
RS-485 Data Direction Control
|
ADDC® (automatic data direction control)
|
• Serial Communication
|
Baudrate
|
50 bps to 921.6 Kbps
|
ESD Protection
|
15 KV
|
Optical Isolation
|
2 KV (TCC-100I/100I-T)
|
• Physical Characteristics
|
Housing
|
Aluminum
|
Dimensions
|
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
|
Weight
|
148 ± 5 g
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Source of Input Power
|
Power input jack
|
Input Voltage
|
12 to 48 VDC
|
Power Consumption
|
TCC-100/100-T: 85 mA @ 12 V
TCC-100I/100I-T: 150 mA @ 12 V
|
Voltage Reversal Protection
|
Protects against V+/V- reversal
|
Over Current Protection
|
Protects against two signals shorted together
|
• Standards and Certifications
|
Safety
|
UL 60950-1
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class B
|
EMS
|
IEC 61000-4-2 (ESD) Level 2,
IEC 61000-4-3 (RS) Level 2,
IEC 61000-4-4 (EFT) Level 2,
IEC 61000-4-5 (Surge) Level 2,
IEC 61000-4-6 (CS) Level 2,
IEC 61000-4-8 (SFMF) Level 1
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failures)
|
Time
|
3,017,857 hrs
|
Database
|
MIL-HDBK-217F
|
• Warranty
|
Warranty Period
|
5 years
|
Dimensions
Pin Assignment
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- RS-232 to RS-422 conversion w ›› ith RTS/CTS support
- RS-232 to 2-wire or 4-wire RS-485 conversion
- 2 KV isolation protection (TCC-100I/TCC-100I-T)
- Wall and DIN-rail mounting
- Plug-in terminal block for easy RS-422/485 wiring
- LED indicators for power, Tx, Rx
- -20 to 60°C operating temperature
- Wide temperature model available (-40 to 85°C )
|
|
|
|
|
|
|