The TCF-142 media converter is equipped with a multiple interface
circuit that can handle RS-232 or RS-422/485 serial interfaces and
multi-mode or single-mode fiber. TCF-142 converters are used to extend
serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up
to 40 km (TCF-142-S with single-mode fiber). The TCF-142 can be
configured to convert either RS-232 signals, or RS-422/485 signals, but
not both at the same time.
Automatic Baudrate Detection
The TCF-142 can automatically detect the serial baudrate. This is an
extremely convenient feature. Even if a device’s baudrate is changed,
the signal will still be transmitted through the media converter without
any data loss.
Ring OperationThe TCF-142 converters can be used to connect serial devices to a
fiber ring. To form the ring, connect the Tx port of one TCF-142 to the
Rx port of a neighboring converter. Once the ring is set up, simply use
the DIP switches to configure the TCF-142 converters for “ring mode.”
When one node transmits a signal, the signal travels around the ring
until it returns back to the transmitting unit, which then blocks the
signal. With the TCF-142, you can set up fiber rings that have a total
circumference of up to 100 km.
Automatic Data Direction Control (ADDC®)
ADDC® is a patented hardware data flow solution developed by Moxa to
handle RS-485 data direction control. ADDC® senses and controls RS-485
data direction automatically, making it unnecessary to use the hand
shaking signal.
Optical Fiber Side
|
Fiber Connector
|
SC or ST
|
Cable Requirements
|
Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 μm
Multi-mode: 50/125, 62.5/125, or 100/140 μm
|
Transmission Distance
|
Single-mode: 40 km
Multi-mode: 5 km
|
Wavelength
|
Single-mode: 1310 nm
Multi-mode: 850 nm
|
Tx Output
|
Single-mode: > -5 dBm
Multi-mode: > -5 dBm
|
Rx Sensitivity
|
Single-mode: -25 dBm
Multi-mode: -20 dBm
|
Point-to-Point Transmission
|
Half-duplex or full-duplex
|
Ring Transmission
|
Half-duplex
|
• RS-232/422/485 Side
|
Connector
|
Terminal Block
|
RS-232 Signals
|
Tx, Rx, GND
|
RS-422 Signals
|
TxD+, TxD-, RxD+, RxD-, GND
|
RS-485-4w Signals
|
TxD+, TxD-, RxD+, RxD-, GND
|
RS-485-2w Signals
|
Data+, Data-, GND
|
Baudrate
|
50 bps to 921.6 Kbps
|
ESD Protection
|
15 KV for all signals
|
• Physical Characteristics
|
Housing
|
Aluminum (1 mm)
|
Dimensions
|
Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
|
Weight
|
320 g
|
• Environmental Limits
|
Operating Temperature
|
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
|
Storage Temperature
|
-40 to 75°C (-40 to 167°F)
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
• Power Requirements
|
Input Voltage
|
12 to 48 VDC
|
Power Consumption
|
140 mA @ 12 V
|
Power Line Protection
|
2 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
|
Voltage Reversal Protection
|
Protects against V+/V- reversal
|
Over Current Protection
|
1.1 A (protects against two signals shorted together)
|
• Standards and Certifications
|
Safety
|
UL 60950-1
|
EMC
|
CE, FCC
|
EMI
|
FCC Part 15 Subpart B Class B, EN 55022 Class B
|
EMS
|
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
|
Green Product
|
RoHS, CRoHS, WEEE
|
• MTBF (mean time between failures)
|
Time
|
780,480 hrs
|
Database
|
Telcordia (Bellcore), GB
|
• Warranty
|
Warranty Period
|
5 years
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- “Ring” and “Point-to-Point” transmission
- Extends RS-232/422/485 transmission up to:
- 40 km with single-mode—TCF-142-S
- 5 km with multi-mode—TCF-142-M
- Compact size
- Decreases signal interference
- Protects against electrical interference and chemical corrosion
- Supports baudrates of 50 bps to 921.6 Kbps
- Wide temperature models available (-40 to 75°C)
|
|
|
|
|
|
|