Digi Connect Sensor is a fully integrated, battery powered cellular gateway with I/O for connecting to a wide range of external sensors. Designed to work in rugged industrial environments, the sensor is the ideal solution for companies looking to add remote monitoring in places where power is not easily available. Its easy installation, reliability and low data usage make remote monitoring possible in areas where it was previously cost prohibitive.
WWAN
|
2G BANDS
|
GSM 850, GSM 900, DCS 1800, PCS 1900
|
3G BANDS
|
FDD B1, B2, B4, B5, B8
|
LTE CATEGORY 1
|
Verizon: Bands 2, 4, 13
AT&T, T-Mobile: Bands 2, 4, 5 with 3G/2G fallback
|
ANTENNA CONNECTOR
|
External SMA
|
SIM SLOTS
|
1, Standard size
|
MANAGEMENT
|
CONFIGURATION AND MANAGEMENT
|
Digi Device Cloud/Local USB to Serial CLI
|
COMMUNICATION PROTOCOL
|
TCP
|
POWER
|
EXTERNAL POWER INPUT RANGE
|
8 VDC to 30 VDC
|
BATTERY AND BATTERY LIFE
|
7.2 V, 14.5 Ah, Lithium thionyl chloride, non-rechargeable, replaceable; Approximately 2 years (@ 2 reads/transmits per day)
|
POWER DRAW, SLEEPING
|
86.4 uW
|
POWER DRAW, PEAK TRANSMIT
|
14.4 Watts
|
ANALOG I/O
|
INPUTS
|
4, Configurable as 4/20 mA or 0-10 VDC Analog inputs
|
INPUT VOLTAGE RANGE
|
0-10.5 V (Analog input)
|
INPUT CURRENT RANGE
|
4-22 mA (Current loop input)
|
DIGITAL I/O
|
PORTS
|
1 digital I/O or pulse counter input
|
INPUT RANGE
|
0-0.6 VCD logic low; 2.2 V-30 VDC logic high
|
MAX INPUT VOLTAGE
|
30 VDC
|
MAX PULSE COUNT FREQUENCY
|
2 KHZ
|
DIGITAL OUTPUT
|
Open collector output, max sink current 450 mA
|
OUTPUT POWER
|
PORTS
|
5
|
OUTPUT VOLTAGE OPTIONS
|
3.3, 5, 15, 24 VDC
|
MAX CURRENT OUTPUT
|
200 mA per sensor
|
ENVIRONMENTAL
|
OPERATING TEMPERATURES
|
-35˚ C to +70˚ C
|
STORAGE TEMPERATURE
|
-40˚ C to +85˚ C
|
RELATIVE HUMIDITY
|
90%
|
BATTERY DISCHARGE
|
<1%/year if stored at +30˚ C
|
PHYSICAL
|
DIMENSIONS (L x W x H)
|
152.4 mm x 108.4 mm (127 mm including glands) x 74.6 mm
|
WEIGHTS
|
264 g
|
LEDS INDICATORS
|
Battery, cellular, sensor and bluetooth
|
ENCLOSURE MATERIAL
|
Lexan
|
REGULATORY APPROVALS
|
SAFETY
|
UL60950-1, CAN/CSA C22.2 No. 60950-1-01, IEC 60950-1:2005 (Second Edition); Am1:2009 + Am2:2013, EN 60950-1:2006 / A11:2009 / A1:2010 / A12:2011 / A2:2013 and EN 60950-22:2006;
Class 1, Division II, groups A,B,C,D; ANSI/ISA 12.12.01:2015,CAN/CSA C22.2 No 213-15, 1st Ed ATEX (pending) EN 60079-0:2012+A11:2013, EN 60079-15:2010, eII 3 G Ex nA nC IIC T6 Gc
|
EMISSIONS
|
FCC part 15 Subpart B class B, EN55022: 2010/AC: 2011 class B, IECS-003 Issue 5: 2012 class B
|
IMMUNITY
|
EN55024:2010
|
WARRANTY
|
PRODUCT WARRANTY
|
3 years, excluding battery
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- Weatherproof enclosure with wide temperature range makes it ideal for use in all environments
- Configurable read and report intervals with threshold and delta alarms
- Low cellular data usage that is consistent and predictable
- Multiple configurable I/O make it possible to connect to multiple sensor types
- External, configurable power outputs eliminate the need for sensor power supplies
- Penta band cellular module enables global connectivity
- Available with bundled cellular service
|
|
|
|
|
|
|